2.9 Functional Test
After all electrical connections to the inverter, batteries, AC source and sub-panel have been
completed, follow these steps to test the installation and the inverter’s operation.
CAUTION:
Use a multimeter to verify the correct DC voltage for your particular inverter
model (i.e., 24-volt battery bank for a 24-volt inverter) and to ensure the polarity of the
battery voltage is correct (battery positive connected to the inverter positive terminal
and the battery negative connected to the inverter negative terminal).
1. Apply battery power to the inverter by closing the DC circuit breaker. The inverter will remain
off , but the green status indicator on the front of the inverter will quickly blink once to indicate
that DC power has been connected and the inverter is ready to be turned on.
2. Prior to turning on the inverter, make sure all AC loads (i.e., appliances) are NOT connected
to the inverter’s output or to any AC outlets powered by the inverter.
3. Lightly press and release the inverter’s ON/OFF switch to turn the inverter on. Verify the
inverter’s status indicator is blinking—indicating the inverter is on.
4. Connect a 10-25 watt light bulb to the inverter output and verify it comes on and shines
normally. DO NOT connect anything larger than a 25-watt light bulb until all wiring and voltages
are confi rmed to be correct.
Info:
The inverter’s AC output voltage will not be correct until a load greater than 5
watts (default setting) is connected to the inverter; or, Search mode is turned off with
a remote display (ME-RC, ME-ARC, or ME-RTR). A 10-25 watt light bulb is used as it is
a suffi
cient load to bring the inverter out of Search mode and up to full voltage.
5. Check the AC output voltage of the inverter by connecting an AC voltmeter to the output
terminals as shown in Figures 2-27, 2-28, or 2-29 (verify the correct output voltages).
6. Press and release the inverter’s ON/OFF switch to turn the inverter off . The inverter’s status
indicator and the connected load should go off .
7. Apply AC power to the inverter’s AC input. After the AC input power is qualifi ed (approximately
15 seconds), the incoming AC power will transfer through the inverter to the inverter’s AC output
and power the light bulb. Verify that the inverter’s status indicator and the light bulb come on.
8. Even though the light bulb is on, the inverter is currently disabled (off ). Press and release the
ON/OFF switch on the inverter to enable (turn on) the inverter.
9. Disconnect the incoming AC power to the inverter. Verify the light bulb remains on and is now
powered by the inverter.
If the inverter passes all the steps, the inverter is ready for use. If the inverter fails any of the
steps, refer to the Troubleshooting section in this manual.
Содержание Magnum Energy MS Series
Страница 1: ...Pure Sine Wave Inverter Charger MS Series Owner s Manual...
Страница 22: ...Page 12 2016 Sensata Technologies Installation Figure 2 4 MS Dimensions MS2012 MS2812 MS2024 MS4024 MS4048...
Страница 23: ...2016 Sensata Technologies Page 13 Installation Figure 2 5 MS Dimensions MS2000...
Страница 26: ...Page 16 2016 Sensata Technologies Installation Figure 2 6 DC and Battery Temperature Sensor Wiring...
Страница 38: ...Page 28 2016 Sensata Technologies Installation Figure 2 13 AC Wiring for Single In Dual Out Con gurations...
Страница 39: ...2016 Sensata Technologies Page 29 Installation Figure 2 14 AC Wiring for Dual In Single Out Con gurations...
Страница 40: ...Page 30 2016 Sensata Technologies Installation Figure 2 15 AC Wiring for Dual In Dual Out Con gurations...
Страница 43: ...2016 Sensata Technologies Page 33 Installation Figure 2 16 AC Wiring for MS2000 Models...
Страница 44: ...Page 34 2016 Sensata Technologies Installation Figure 2 17 AC Wiring for MS2000 15B 20B Models...