This  manual  consists  of  contents  about  how  to  use  the  gas  detector.  All  operators 
involved in the operation and maintenance of the equipment should read carefully before 
operation. Caution or warning signs contained in the manual will always be followed. The 

defects  or  failure  of  the  product  may  be  caused  if  our  products  are  used  outside  the 
scope  of  the  environment  and  the  product

s  SPEC  as  specified  in  the  manual  or  if  the     

equipment  is  used  by  workers  not  qualified  for  the  maintenance  and  repair  of  the 
products.  SENKO  is  not  responsible  for  such  products

  failure.  Because  our  product 

includes  a  default  installation  circuit  diagram,  an  installation  must  be  carried  out  by  a 

qualified  person.  Also,  regular  calibration  and  alarm  check  on  the  device  must  be 
performed  by  a  qualified  worker.  SENKO  recommend  you  that  monthly  calibration  and 
check be performed for the accuracy and reliability of the device. Should a problem occur, 

please contact the SENKO.     

 

 
WARRANTY 

 

 

SENKO  warrants  the  SI  series  product  for  24  months  from  the  shipment  date.  SENKO 
will  repair or replace  a defected  product  under  the  warranty  free  of charge with  a  new 

product.  However,  components,  such  as  sensors,  lamps,  and  batteries,  which  will  have 
their  lives  shortened  as  used  are  not  applicable  to  this  warranty.  If  a  product  was 
purchased a route that SENKO does not recognize, a product with malfunction cannot be 

repaired  or replaced  free  of charge  when  mechanical  damages  or deformations  happen 
from improper use of the product by a consumer or when product failures occur because 

calibration  or  replacement  of  parts  has  not  been  made  according  to  a  procedure  of 
manual.   
 

 
Should our product have defect or other quality problems, all the costs incurred except 
the shipping cost will be borne by SENKO during the warranty period. After the warranty 

period, all the costs of repair, replacement, transportation of products or parts, in 
principle, will be borne by customers. SENKO is not liable for any indirect or incidental 

loss or accidents that may occur while using the product. The warranty is limited to 
replacement of parts and products. This warranty is applicable only to users who have 
purchased the product from authorized sales offices or representatives specified by 

SENKO. Warranty repairs must be made through a SENKO-designated A/S center with 
experienced technicians. 

 

Senko Co., Ltd.  

73, Oesammi-ro 15beon-gil, Osan-si, Gyeonggi-do, Korea 

TEL. 031-492-0445 FAX.031-492-0446 

www.senko.co.kr 

WARNING

 

 
Read this manual carefully before using the instrument. The instrument

 

will perform as designed only if it is used and maintained in accordance 
with the manufacturer's instruction. Otherwise, it could fail to perform as

 

designed and persons who rely on this  instrument for their  safety could 
sustain serious personal injury or death.

 

Содержание SI-100IA

Страница 1: ...I 100IM MAIN UNIT SI 100IA ALARM DISPLAY UNIT SI 1 0 0 IM 3 1 2 PPM LEL V SI 1 0 0 IA 3 1 2 PPM LEL V SI 1 0 0 IA 3 1 2 PPM LEL V SPARE BLANK Multi G a s Monitor SI 1 0 0 IM SI 1 0 0 IA SI 1 0 0 IC U...

Страница 2: ...and Description 4 Product s Dimension 6 5 Internal Configuration 3 channel basis 7 6 Terminal Configuration 8 7 Product Instruction for Use 9 SI 100IM Main Alarm Unit SI 100IA Alarm Display Unit 8 Des...

Страница 3: ...chased a route that SENKO does not recognize a product with malfunction cannot be repaired or replaced free of charge when mechanical damages or deformations happen from improper use of the product by...

Страница 4: ...nnel display of a corresponding Alarm Unit on the Main Alarm Unit through the transmitted data so that a user at a glance can notice which alarm unit has given an alarm signal The three Alarm outputs...

Страница 5: ...4Channel While the 24V DC power is introduced for battery charge and discharge and for the power of the Alarm Unit this unit can make an alarm generating unit display by communicating with the Alarm U...

Страница 6: ...ale 13 Alarm Output Fault SPDT Relay Dry contact Signal Output ON OFF Alarm 1 SPDT Relay Dry contact Signal Output ON OFF Alarm 2 SPDT Relay Dry contact Signal Output ON OFF Alarm 3 SPDT Relay Dry con...

Страница 7: ...IMENSION SI 1 0 0 IA SI 1 0 0 IM 3 3 1 2 1 2 V PPM LEL 130 40 110 130 40 SI 1 0 0 IM 3 1 2 PPM LEL V SI 1 0 0 IA 3 1 2 PPM LEL V SI 1 0 0 IA 3 1 2 PPM LEL V SPARE BLANK Multi G a s Monitor SI 1 0 0 IM...

Страница 8: ...r Switch 8 Built in BATTERY 9 SMPS 24V DC Power Supply 3CH 1 2A 6CH 2 2A 10CH 3 2A 12CH 4 5A 10 FRONT DOOR LINE LOAD ALARM 3 ALARM 2 ALARM 1 12V OUT GND 0V 24V 24VS SENSOR SIG 0VS 12V OUT 4 20mA GND F...

Страница 9: ...OUT 4 20mA GND FAULT ALARM 3 ALARM 2 ALARM 1 ALARM 3 ALARM 2 ALARM 1 12V OUT GND 0V 24V GAS DETECTOR MAIN UNIT SI 100IM ALARM UNIT SI 100IA 24V 4 20mA GND 3Wire 24VS SENSOR SIG 0VS 12V OUT 4 20mA GND...

Страница 10: ...Unit SI 100IA Alarm Display Unit When the power is turned on the device will display the product software version 1 00 A for 1 sec and an ID of the Unit from 01 to 12 seconds for 4 seconds Then after...

Страница 11: ...efault 15 AL 2 Secondary Alarm Setting Value default 50 AL 3 Tertiary Alarm Setting Value default 70 Span Concentration of Calibration Gas default 25 N AL The number of calibration depending on the ca...

Страница 12: ...rm the device will display the voltage in process of charging and tell you about a state of charging spare power or a state of fully charged Return Switch Once you solve the problem with the gas detec...

Страница 13: ...ration bar graph will arise just as shown in the figures As a concentration rises as shown in the figures the primary secondary and tertiary alarm lamp will be turned on according to an alarm value th...

Страница 14: ...ill be changed Gas Calibration After adjusting the calibration gas concentration SCAL will be displayed If you press the Switch at this status a current gas value will be displayed Zero will be displa...

Страница 15: ...at once Secondary Alarm Value Change default 50 LEL Press the setting switch while AL 2 is shown a default number will be displayed If you need a change while a number is marked change the number by p...

Страница 16: ...ration Range LOW RANGE default 0 Press the Setting Switch when LRNG is displayed and a default value will be displayed Press the UP and DOWN Switch while a figure is being displayed You can change its...

Страница 17: ...when an alarm concentration level is reached Change in 12V Voltage Output default 321 17Press the Setting Switch when 12VO is displayed and a default value will be displayed Press the UP and DOWN Swit...

Страница 18: ...rmal range the alarm and the output will be still stored Even If the device is interlocked with other equipment and thus alarm is repeatedly on and off depending on a concentration a value can changed...

Отзывы: