Figure 5.18
RS485 communications for multiple inverters
V1000 data collector logger made by Senergy is recommended when
NOTE
multiple inverters are connected; Modbus address configuration can
be generated
automatically in Senergy logger. Otherwise, if with other brand logger, you need
set Modbus address manually through SE Touch APP in mobile phone, for details
referring to
Accessary
Modules Installation Guide.
If
multiple inverters are connected, turn
RS485 Resistance
to
ON
from
the dial switch of the inverters
on the end of the chain.
Ensure that the appropriate length of communications cable between every
two inverters is less than 200 m when RS485 communications mode is
implemented for multiple inverters.
5.4.2 Connecting RS485 Communications Cables
Figure 5.19 shows the standard RS485 wiring diagram: