![Senergy SE 10K Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/senergy/se-10k-series/se-10k-series_user-manual_1239620014.webp)
Figure 2.7
The circuit diagram of 5K/6K/8K/10K.
Figure 2.8 shows the circuit diagram for 12K/15KTL.
Figure 2.8
T
he circuit diagram of
12K/15KTL
.
2.4.3 Working Modes
Three working modes of the inverter are shown as follows: standby, operating, and
shutdown. Table 2.1 shows the conditions for the inverter to switch between working
modes.
Table 2.1 Working modes description
Modes
Description
Standby
The PV inverter enters the standby mode when the input voltage of PV Strings
can enable auxiliary power supply to run, but cannot meet the inverter operation
requirements.
Operating
When the PV inverter is grid-tied and generates electricity, it
> tracks the maximum power point to maximize the PV String output.
> converts DC power from PV strings into AC power and feeds the power to the
power grid.