ADDRESS
(4x)
ADDRESS
OFFSET
REGISTER
DESCRIPTION
W/R
TYPE
40078
77
Status register:
BIT 0 LSBIT (RO)
Bit 0 = 1 Exceeded thr
Stable weighing
BIT 1 (RO)
Bit 1 = 1
The cell has reached full scale
BIT 2 (RO)
Bit 2 = 1
Net weight is < 0
BIT 3 (RO)
Reserved
BIT 4 (RO)
Bit 4 = 1
Weighing is stable
BIT 5 (R/W)
Only if the modbus-controlled
output mode has been selected:
Bit 5 = 1
The digital output is activated
Bit 5 = 0
The digital output is deactivated
BIT 6 (RO)
Bit 6 = 1 if the digital output is
high
BIT 7 (RO)
Bit 7 = 1 Exceeded threshold
with hysteresis
BIT 8 (RO)
Bit 8 = 1 The tare tracker
intervened
BIT 9..15 Not Used
intervened (if enabled)
R/W
UNSIGNED
16 BIT