USB PORT

The module is designed to arrange data according to the modes defined by the MODBUS protocol. It has a micro 

USB connector on the front panel and can be configured using applications and/or software programs. The USB 

communication has priority over the RS485 communication.

 

The USB serial port uses the following communication parameters: 

2400,8,N,1

The USB communication port 

responds exactly like the  RS485 port with the exception of the communication parameters. During the use of the 

USB port, the bus will be inactive; it will reactivate automatically a few seconds after the last message exchanged 

on the USB port. EASY SETUP is the software to use for the configuration. For more information, visit www.sene-

ca.it/products/z-4tc

Check that the device in question is included in the list of products supported by the Easy Setup APP in the store.

5/8

CU

MICROO TG

-A--

CU

MICROB

-A-

CU

MICROB

-A-

Android APP 

configuration

PC software 

configuration

Содержание Z-4TC

Страница 1: ...T module with Modbus protocol on RS485 SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other languages and the configuration software visit...

Страница 2: ...pecific documentation is available at www seneca it products z 4tc Important Obstructing ventilation slots with any object is prohibited Installing the module next to devices that generate heat is pro...

Страница 3: ...0 5 W 24Vdc Max 1 W INPUTS Voltage input Bipolar with F S 160 mV with 16 bit resolution Input impedance 10 MOhm DMRR 60 dB 50 Hz 54 dB 60 Hz Thermocouple input TC type J K R S T B E N Automatic detec...

Страница 4: ...that obstruct the ventilation slots Avoid mounting modules over equipment generating heat Installation in the bottom part of the switchboard is rec ommended Insertion in the DIN rail As shown in figur...

Страница 5: ...ion port responds exactly like the RS485 port with the exception of the communication parameters During the use of the USB port the bus will be inactive it will reactivate automatically a few seconds...

Страница 6: ...the type of input selected 1bit 5 V or 0 1 C 40014 IN CH2 Channel measurement value depending on the type of input selected 1bit 5 V or 0 1 C 40015 IN CH3 Channel measurement value depending on the ty...

Страница 7: ...al protection shield recom mended 7 8 2 3 Vac Vdc Vac Vdc 1 Power supply Terminals 2 and 3 can be used to provide the module with power supply as an al ternative to the connection using the Z PC DINx...

Страница 8: ...ltage input Possibility to set the measurement scale values by adjusting ISM measurement scale start FSM measure ment full scale 10000 mV or 0 20000 A Possibility to set the measurement scale values b...

Отзывы: