background image

MODULE LAYOUT

Dimensions LxHxD

 17.5 x 102.5 x 111 mm; 

Weight:

 

110 g; 

Enclosure:

 PA6, black

17.5 mm

111 mm

102.5 mm

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol            indicates conditions or actions that put the user's safety at 

risk. The word 

ATTENTION

 preceded by the symbol            indicates conditions or actions that might damage the 

instrument or the connected equipment.

The warranty shall become null and void in the event of improper use or tampering with the module or devices 

supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manu-

al are not followed.

WARNING

: The full content of this manual must be read before any operation. The module must only be used by 

qualified electricians. Specific documentation is available at www.seneca.it/products/z-4tc

Important: Obstructing ventilation slots with any object is prohibited. 

Installing the module next to devices that generate heat is prohibited.

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The 

symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to 

recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electro-

static discharges. Take appropriate measures during any operation.

LED

STATUS

LED meaning

PWR Green

ON

The device is powered correctly

FAIL yellow

Flashing

Wrong setup

FAIL yellow

ON

Anomaly or fault

RX Red

Flashing

Receipt of packet completed

RX Red

ON

Anomaly / Check connection

TX Red

Flashing

Transmission of packet completed

SIGNALS VIA LED ON FRONT PANEL

2/8

Содержание Z-4TC

Страница 1: ...T module with Modbus protocol on RS485 SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other languages and the configuration software visit...

Страница 2: ...pecific documentation is available at www seneca it products z 4tc Important Obstructing ventilation slots with any object is prohibited Installing the module next to devices that generate heat is pro...

Страница 3: ...0 5 W 24Vdc Max 1 W INPUTS Voltage input Bipolar with F S 160 mV with 16 bit resolution Input impedance 10 MOhm DMRR 60 dB 50 Hz 54 dB 60 Hz Thermocouple input TC type J K R S T B E N Automatic detec...

Страница 4: ...that obstruct the ventilation slots Avoid mounting modules over equipment generating heat Installation in the bottom part of the switchboard is rec ommended Insertion in the DIN rail As shown in figur...

Страница 5: ...ion port responds exactly like the RS485 port with the exception of the communication parameters During the use of the USB port the bus will be inactive it will reactivate automatically a few seconds...

Страница 6: ...the type of input selected 1bit 5 V or 0 1 C 40014 IN CH2 Channel measurement value depending on the type of input selected 1bit 5 V or 0 1 C 40015 IN CH3 Channel measurement value depending on the ty...

Страница 7: ...al protection shield recom mended 7 8 2 3 Vac Vdc Vac Vdc 1 Power supply Terminals 2 and 3 can be used to provide the module with power supply as an al ternative to the connection using the Z PC DINx...

Страница 8: ...ltage input Possibility to set the measurement scale values by adjusting ISM measurement scale start FSM measure ment full scale 10000 mV or 0 20000 A Possibility to set the measurement scale values b...

Отзывы: