User Manual
RM169-1
ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY
BE REPRODUCED WITHOUT PRIOR PERMISSION.
www.seneca.it
Doc. MI004760-E
Rev. 0
Pag. 4
Country allowed
(4)
ALB-AND-AUT-BEL-BIH-BLR-BUL-CYP-CZE-D-DNK-E-EST-F-FIN-G-GRC-HNG-HOL-HRV-I-IRL-ISL-LIE-
LTU-LUX-LVA-MDA-MKD-MLT-MNE-NOR-POL-POR-ROU-RUS-S-SRB-SUI-SVK-SVN-TUR-UKR
Allowed use according to ERC Recommendation 70-03
RM169-1
Frequency (MHz) Annex
(1)
E.R.P
(2)
Duty Cycle
(3)
Country
(4)
with
restriction of use
169,400 – 169,475
1
≤ 500 mW
≤ 1 %
BLR-RUS-UKR
169,400 – 169,475
2
≤ 500 mW
≤10 %
BLR-RUS-UKR
NOTE:
Before to install the device check always the latest version of ERC Recommendation 70-03 in order to verify
any restriction and limitation in terms of E.R.P and Duty Cycle
(1) Annex 1.xxx refer to SRD (Short Range Device), Annex 2 refer to Tracking, Tracing and Data Acquisition.
(2) E.R.P. = Max Effective Radiated Power allowed from radiomodem and associated antenna takes into
consideration transmitter power output, transmission line attenuation, RF connector insertion losses and
antenna gain
(3) Duty Cycle is defined as the ratio, expressed as a percentage, of the maximum transmitter “on” time on
one carrier frequency, relative to a one hour period
(4) The CEPT country codes can be seen under
http://www.cept-org/cept/cept-country-codes