background image

 

User Manual

 

RM169-1

 

 

Pag. 29 

Doc. MI004760-E 

Rev. 0 

www.seneca.it 

ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY 

BE REPRODUCED WITHOUT PRIOR PERMISSION. 

 

Repetition Number: 

In this field you can define the number of repetitions of the packet if the acknowledge is not received. This 

function is available only when the ACK is enabled. 

 

Nak To DTE

If enabled, the radio modem sends a NAK character (ASCII 21) to the DTE in the case where all repetition are 

sent without receiving any acknowledge. This function is available only when the ACK is enabled. 

 

RF Power:

 

Allows the choice between three different levels of power: High, Medium, Low. 

 

PwSavOff:

 

Inserting in this field a number greater than 0, the power save feature is enabled. This is the value corresponding 

to the off period of the energy savings cycles. The step is in the tens of milliseconds. The Master unit is always 

active but uses this value to size the length of the preamble of the packets sent to a sleeping device (digipeater 

or slave). If you intend to use the power save feature 

all units in the network must have the same "PwSavOff" 

value

. Note: If the Power Save feature is used, only the Master unit can always receive characters from the 

serial line; the Slave can only do it during the PwSava period. 

 

PwSava:

 

When the Power Save is used, by this field you can set the time interval in which the radio modem remains 

operational (On) after it has been temporarily enabled by an event (i.e.: reception of a packet radio). This value 

is in steps of hundreds milliseconds. This field is also used to differentiate the device between Master and Slave:

 

a value of 255 identifies the unit as Master

 and keeps it always On. The unit so configured is therefore not 

affected by the ON-OFF cycles, but the packets are sent with a suitable (longer) preamble time in order to be 

received by the slave devices that use the Power Save. 

 

Channel sel A LBT:

 

In this box you choose the radio channel to be used. If you want to use the agility feature (transmission on the 

less noisy channel between the active channels), you can select more than one radio channel. The maximum 

number of active channels is dependent on the canalization setting.

 It is mandatory that in the same network 

all the radiomodems use the same radio channels

. It is possible to enable the LBT feature: the radio modem 

waits for the channel to become free before proceeding with the transmission of the packet.  

When the LBT function is active the device counts the seconds of data ON-AIR transmission in order to operate 

according to EN300 220-1 standards that require to not exceed a transmission time of 100 seconds in a 1 hour 

period. After 100 seconds the device stop the transmission and wait the 1 hour period before to allow a new 

transmission. 

 

AES Enable:

 

Enable or disable the AES-128 data encryption. In the transmitted packet, the encoding and decoding is done 

on the payload only. 

 

Set AES Key:

 

By pressing this button a window opens where the value of the 128-bit AES key is set. The user must insert 16 

ascii characters. The configurator displays an error message if, upon pressing the "OK" button, the string of the 

AES key is incomplete (i.e. less than 16 characters are inserted). 

Note

: If the AES is used, all the radiomodems in the same network 

must use the same AES key

. If the key 

setting is not the same, the data transiting on the serial line are not interpretable by the connected hardware. 

Содержание RM169-1

Страница 1: ...L RM169 1 RADIOMODEM 169MHz with RS232 RS485 interface and complies with the Directive 2014 53 EU RED SENECA S r l Via Austria 26 35127 PADOVA PD ITALY Tel 39 049 8705359 8705355 Fax 39 049 8706287 ww...

Страница 2: ...HOUSEHOLDS WITHIN THE EUROPEAN UNION 7 8 GENERAL DESCRIPTION 8 9 INSTALLATION 10 9 1 Mechanical 10 9 2 Electrical wiring 10 9 3 Antenna 11 10 CONFIGURATION 12 10 1 System requirements 12 10 2 Configu...

Страница 3: ...ng to a third party leasing renting transportation copying editing translating modifying into another programming language or reverse engineering for any intent is forbidden without the written consen...

Страница 4: ...RUS UKR NOTE Before to install the device check always the latest version of ERC Recommendation 70 03 in order to verify any restriction and limitation in terms of E R P and Duty Cycle 1 Annex 1 xxx...

Страница 5: ...impedance 50 Digital Input Rating digital input 5 24 Vdc 3 20 Vac ZDIGITAL INP Digital input impedence 2 2 k Digital Output Digital output rating Normally Open NO 24 Vac 0 5 A 32 Vdc 1A IA B LINES Max...

Страница 6: ...send it at its own expense at the headquarters of the Italian Supplier The product will be repaired or replaced by the Supplier at no costs to the Buyer The Buyer will pay all the shipping costs for t...

Страница 7: ...general public walkway that gives general public access Do not install the equipment close to a heat source or in damp conditions and direct sunlight is also to be avoided The device must not be expo...

Страница 8: ...anced Encryption Standard ensures transmitted data security A power saving function is built in to activate inputs only when required allowing for extended battery life Function available for each ope...

Страница 9: ...le Yes 1 route Yes 255 route No No No Yes 1 route Yes 1 route Broadcasting Yes No No No No No No Address from DTE Yes No No No No No No Address to DTE Yes No No No No No No Rx address for Tx Yes No No...

Страница 10: ...OFF before connecting or disconnecting the serial connection cable It should be ascertained that different devices used have the same ground potential Before connecting any power cables the output vo...

Страница 11: ...SION 9 3 Antenna L antenna deve essere installata in spazio libero e posto ad una distanza di almeno 10 cm da materiali conduttori Quando l antenna installata all esterno essenziale connettere lo sche...

Страница 12: ...of the button from Turn ON to Turn OFF and by the activation of the Read and Write buttons If when Turn ON is pressed the button blink green wait the end of the blink before proceding with normal oper...

Страница 13: ...ou load a configuration file using the menu File Open or if the configuration is read by a radio modem unit Toolbar The Toolbar on the upper side of the screen contains File Options and Help Menus Eac...

Страница 14: ...RESERVED NO PART OF THIS PUBLICATION MAY BE REPRODUCED WITHOUT PRIOR PERMISSION www seneca it Doc MI004760 E Rev 0 Pag 14 Help menu Index F1 Open the Help file About Display the version information ab...

Страница 15: ...he Master s digital inputs every input of the four available modes may trigger this event 2 The expiration of the timer dedicated to the periodic sending of the data cycle update On the Slave unit eve...

Страница 16: ...eld you cannot insert a value less than the value of the time interval assigned to the field Sensor stabilization time Safety options frame Time sets the value of the safety timer whose time base is s...

Страница 17: ...g It is mandatory that in the same network all the radiomodems use the same radio channels In Mirror mode the LBT function cannot be activated 11 2 MODBUS LOW ENERGY OPERATING MODE In this modality th...

Страница 18: ...ent in the network The allowed values range from 1 to 16 Ext node address In this field the address of the external modbus node is set which it must be identical to the address assigned to the modbus...

Страница 19: ...dress of this radiomodem Each unit must have a unique address In the Master device the maximum value of this field is dependent on the number of units in the network parameter selected in the field Un...

Страница 20: ...field you can set the number of repetitions of a packet when there is no answer RF Power Allows the choice between three different power levels High Medium Low If the value of the RSSI present in the...

Страница 21: ...ically widespread in mountainous areas or where there are many obstacles The node addresses must be unique in the same network can exist up to 254 nodes distributed according to need among the slave u...

Страница 22: ...r takes the initiative of the transmission Internal node address It is the address of the modbus node related to the internal peripherals of the radiomodem Set a non zero value if you want to use its...

Страница 23: ...the safety timer expires the relay contact of digital output will be forced to open Relays to Closed when the safety timer expires the relay contact of digital outputs will be forced to closed Its add...

Страница 24: ...his field is used to set the communication speed of the serial line The legal values are 1200 2400 4800 9600 19200 38400 57600 bps Parity By this selector it is possible to enable and choose the parit...

Страница 25: ...onds the device stop the transmission and wait the 1 hour period before to allow a new transmission AES Enable Enable or disable the AES 128 data encryption In the transmitted packet the encoding and...

Страница 26: ...is completed i e when 1024 bytes are received or when the Time DTX timer is expired the radio modem send the packet to the target unit It is possible to include in the radio path up to 8 digipeater to...

Страница 27: ...e safety timer expires the relay contact of digital output will be forced to open Relays to Closed when the safety timer expires the relay contact of digital outputs will be forced to closed Its addre...

Страница 28: ...downloaded to the DTE will be preceded by the address of the sender This feature allows the identification of the source of the message Baud rate This field is used to set the communication speed of...

Страница 29: ...of 255 identifies the unit as Master and keeps it always On The unit so configured is therefore not affected by the ON OFF cycles but the packets are sent with a suitable longer preamble time in orde...

Страница 30: ...restore the normal operational functionality On the page 2 of the configuration program enter the same system code and the same power_save settings as the one of the remote radiomodem you want make t...

Страница 31: ...I read from the slave D is referred to the reception of the digipeater C while the RSSI read from the master A is referred to the reception of the digipeater B If you wish to use the readings of diagn...

Страница 32: ...nt16 format In order to read the register select the address node set the starting address and the number of register to read max 8 Write digital output Use Modbus command Write sigle coil 0x05 or Wri...

Страница 33: ...ess Address of first register always 0064 3 4 Register quantity Value in function of external node register quantity 5 6 Number of bytes to follow CRC not included value in function of external node r...

Отзывы: