EN-10
min. 105 mm
Interior unit
min. 155 mm
min. 250 mm
min. 20 mm
Marked places of installation with the help of mounting boards of the interior unit.
or
or
The connective pipe can be
lead from the back, right,
bottom or from the left back
side.
right side
front side
bottom
back
left back side
left
side
Note: The drain hose must
not be raised too much.
When installing the piping
on a thin board or on
the wall in a metal net, it
is necessary to insert a
wooden board between the
wall and the pipe or to wrap
the piping in 7-8 layers of
insulation tape.
The connective pipe must
be wrapped in an insulating,
impermeable material.
Soft plastic insulting,
impermeable material 8
mm thick.
Caution:
The maximum permitted
length of connective piping
is 10 m.
The maximum permitted
distance (height-wise)
between the room and exterior
unit is 5m.
INSTALLATION SKETCH
Exterior unit
min. 500 mm
min. 300 mm
min.
500 mm
min. 500 mm
min. 300 mm