EN-9
Type
SAC 0900
SAC 1200
SAC 2400
Power supply
220-240 V~ 50 Hz
Rated cooling output (W)
2600
3300
6500
Rated heating output (W)
2800
3650
7200
Rated input
power
(W)
Cooling
995
1260
2495
Heating
870
1250
2560
Additional heating
----
----
----
Rated input
current
(A)
Cooling
4,5
5,6
11,3
Heating
4
5,5
12,2
Additional heating
----
----
----
Air circulation capacity (m
3
/h)
400
450
1100
Dehumidifying capacity (l/h)
0,8
1,2
3,0
Degree of coverage (protection
against harmful water penetration)
IP20 (interior unit) IP24 (exterior unit)
Protection class
I
Cimate type
T1
Total amount of coolant
(R407C) in grams
670
730
2200
Noise level
dB(A)
Interior unit
39
40
51
Exterior unit
50
51
60
Net weight
(kg)
Interior unit
10
10
15
Exterior unit
26
33
60
Dimensions
(mm) hxwxd
Interior unit
290x800x183
290x800x183
330x1080x220
Exterior unit
500x665x295
500x830x310
690x910x370
Inside protection
3,15A / type of fuse T
3,15A / type of
fuse T
3,15A / type of
fuse T
WARNING
1. The aforementioned values of noise were measured in a laboratory prior to product distribution.
2. The rated cooling and heating value was tested under the conditioned mentioned below:
Cool mode
indoor
27 °C (DB)
19 °C (WB)
outdoor
35 °C (DB)
24 °C (DB)
Heat mode
indoor
20 °C (DB)
15 °C (WB)
outdoor
7 °C (DB)
6 °C (WB)
DB – dry bulb thermometer
WB – wet bulb thermometer
3. With regards to continual development, the manufacturer reserves the rights to change technical data
without prior warning.
4. The scheme of electro-installation of the air-conditioner (interior/exterior units) is provided with the unit.
5. In case the electric cord is damaged, contact a service technician, or qualified person or it may pose
danger of injury.