Troubleshooting  

Warning: De-energize the unit using proper LOTO procedures 

before performing any cleaning, lubrication, 

maintenance, or trouble shooting. 

Problem 

Cause 

Solution 

Machine will not stop when 
stop button is activated

 

Defective stop button

 

Check continuity (N.C), replace if bad

 

Malfunctioning reverse contactor

 

Check each leg of forward side of 
contactor for continuity.  There should 
be no continuity.  If there is, consult 
factory for replacement part.

 

Machine will not run in forward 
or reverse 

 

No Power

 

Check power supply

 

Key-switch off/

e-stop actuated 

Turn on 

Overload tripped in panel

 

Reset, wait for it to cool down

 

Control transformer fuse blown

 

Remove fuse and check for continuity, 
replace if bad

 

Stop button stuck “in”

 

Check buttons

 

Loose wire in panel

 

Check terminal strip for disconnected 
or loose wires.  Reconnect and tighten 
loose wires to proper location on strip

 

Machine not running forward or 
r power light is not 
illuminated

 

Defective contact block on stop 
button

 

Check block for continuity, replace if 
bad

 

Overload tripping

 

Motor overheating

 

Check motor cooling fan for objects 
obstructing air flow

 

Dirty or unlubricated cutting head

 

Thoroughly clean and lubricate 
machine

 

Low voltage/voltage drop >3%

 

Check voltage at power supply

 

Defective motor

 

Conduct amperage test, contact factory 
for replacement if necessary

 

Shred capacity low

 

Unlubricated cutting head

 

Clean and lubricate cutting head

 

Low voltage / voltage drop >3%

 

Check voltage at power supply

 

Current relay set too low

 

See maintenance section, contact 
factory

 

Machine will only run in 
forward OR reverse

 

Defective button

 

Check contact blocks and continuity

 

Loose wire

 

Check buttons for loose/disconnected 
wires and reattach

 

Current Relay

 

Check for continuity or disconnected 
wires and replace if necessary

 

Motor hums or buzzes but 
doesn’t run

 

Contactor malfunctioning

 

Check contactors and replace if faulty

 

Defective motor

 

Check motor and replace if faulty

 

Single phasing (on 3

-phase units 

only) 

Check each leg and fuse of incoming 
power

 

 

 

Содержание 0303

Страница 1: ...US 800 225 9293 508 366 1488 Email service semshred com Fax 508 366 6814 Website www semshred com SEM Model 0303 POP 0044 Rev 0 Created 8 21 18 ECN 00213 This manual covers All Model 0303 configuratio...

Страница 2: ...n this collateral SEM does not warrant that the equipment will work properly in all environments and applications and makes no warranty or representation either implied or expressed with respect to th...

Страница 3: ...RE INTENDED FOR THE DESTRUCTION OF SOLID STATE MEDIA ONLY ATTEMPTING TO SHRED ROTATIONAL DRIVES WILL VOID WARRANTY SHREDDING OF ROTATIONAL HDDs BY USING AN SSD UNIT OR THE COMBO SSD CHUTE COULD CAUSE...

Страница 4: ...tine shredder maintenance including cleaning Never operate this or any other machine while under the influence of drugs alcohol or medications Never wear loose fitting clothing ties or jewelry while i...

Страница 5: ...g and Installation 9 Uncrating 9 General Installation 9 Modular Output Conveyor optional 10 Electrical refer to licensed electrician 11 Electrical Schematics 12 Operation 14 Pre Start Up 14 Start Up 1...

Страница 6: ...M offers three different cutter configurations at various sizes discussed below Hard drive shredders at 1 5 and 0 75 shred widths can shred SSDs but it is not recommended Solid state only shredders at...

Страница 7: ...es Feeding a standard rotational hard disk drive into an SSD unit or the combo SSD chute will jam the machine and could result in permanent damage Unacceptable Media The following materials should nev...

Страница 8: ...0 General Assembly Drawing Shredder Cabinet Collection Bin Access Door Feed Chute Control Panel Top Cover Serial Number Tag Location Back Panel Power Cord Filter Access Panel left side Current Relay P...

Страница 9: ...8 POP 0044 Rev 0 Collection Bins single chute units have one bin PLC Shredding Chamber Electrical Box Forward Contactor Reverse Contactor Overload Current Transformer Motor...

Страница 10: ...lbs Pry bar and hammer Power drill with Phillips head bit Gloves and safety eyewear Strap cutters Uncrating Remove sides of crate hammer and pry bar Cut straps holding Model 0303 strap cutters Remove...

Страница 11: ...that is on the conveyor to secure the conveyor to the shredder Electrical schematic including conveyor outlet available upon request contact SEM customer service ITEM QTY DESCRIPTION ITE M QT Y DESCR...

Страница 12: ...ve into the appropriate chute if it does not take the drive the rotation is wrong o A licensed electrician should be able to fix this by swapping two leads on the plug A customer supplied disconnect s...

Страница 13: ...at upon request 208V 3PH 60Hz 230V 3PH 60Hz 460V 3PH 60Hz 380 415V 3PH 50Hz Detail Unit Voltage Phase Frequency Incoming Power IP 208 3 60 230 3 60 380 415 3 50 460 3 60 Shredder Motor Mot A HP 3 FLA...

Страница 14: ...13 POP 0044 Rev 0...

Страница 15: ...t with the two leftmost buttons removed Start Activates the cutting chamber Reverse Reverses the rotation of the cutting chamber o Must be held down Stop Deactivates the cutting chamber and stops the...

Страница 16: ...t the same time Clearing a Jam In the event of a jam ensure that all personnel are clear of both the input chute and the cutter head Hold the reverse pushbutton for three to five seconds This will cau...

Страница 17: ...r damage and clear air inlet Remove side guards and visually inspect drive components for leaks or damage Replace all guards Empty waste collection bin Weekly cleaning after each 40 hours of operation...

Страница 18: ...filler and drain plugs Wait for oil to drain out change plug seal Clean magnetic drain plug Replace drain plug and refill to proper level using a high grade petroleum based rust and oxidation inhibit...

Страница 19: ...ange version with two knobs Use the knob labelled threshold Warning Overadjustment can cause the overload to trip which will not allow the device to start until the overload is reset The overload will...

Страница 20: ...BAR OUTSIDE SPACER DRIVE SIDE 27 5 34267 SSD CUTTER STYLE 1 9 4 34584 HD TIE BAR SPACER DRIVE SIDE 28 4 34268 SSD CUTTER STYLE 2 10 2 35483 HD TIE BAR SPACER IDLER SIDE 29 6 34269 SSD CUTTER STYLE 3 1...

Страница 21: ...IE BAR OUTSIDE SPACER DRIVE SIDE 27 13 34276 SSD SHAFT SPACER 9 1 34463 SIDE PLATE DRIVE SIDE 28 2 110016 SPUR GEAR 10 1 34462 SIDE PLATE SPUR GEAR SIDE 29 1 34887 DIVIDER SHAFT SPACER 11 1 34582 END...

Страница 22: ...63 SPACER 3 1 N A REDUCER CONSULT FACTORY 13 2 33772 SIDE PLATE 4 1 33615 DRIVE SHAFT 14 1 33772 SIDE PLATE 5 2 33616 DRIVE SHAFT CUTTER 15 2 33625 END PLATE 6 1 33617 IDLE SHAFT CUTTER 16 2 110016 SP...

Страница 23: ...G BLOCK 11 2 33619 75 WEAR BLOCK 3 1 N A REDUCER CONSULT FACTORY 12 3 33617 75 IDLE SHAFT CUTTER 4 1 33615 DRIVE SHAFT 13 4 33616 75 DRIVE SHAFT CUTTER 5 1 33618 IDLER SHAFT 14 5 33616 75 SHAFT HEX SP...

Страница 24: ...RIVE SHAFT 16 4 34269 CUTTER STYLE 3 5 1 33618 IDLER SHAFT 17 13 34276 INSIDE SHAFT SPACER 6 4 111907 BEARING 18 30 34575 INSIDE TIE BAR SPACER 7 1 34449 CUTTERHEAD END PLATE REAR 19 7 34576 REAR COMB...

Страница 25: ...rward or reverse power light is not illuminated Defective contact block on stop button Check block for continuity replace if bad Overload tripping Motor overheating Check motor cooling fan for objects...

Страница 26: ...position good for vehicles 5 iWitness P N iWitness Software and barcode scanning system for easily logging and tracking media Comes with laptop scanner and software Below is a list of spare parts and...

Страница 27: ...366 1488 Toll Free US 800 225 9293 Address 5 Walkup Drive PO Box 1045 Westborough Massachusetts 01581 Follow us on social media Facebook https www facebook com semshred Twitter https twitter com semse...

Отзывы: