SEM 0303 Скачать руководство пользователя страница 16

15

 

POP-0044 – Rev. 0

 

 

Start Up 

PPE:

 SEM recommends wearing safety glasses, gloves, and a mask while operating this device. 

Turn key switch on and press the forward pushbutton. 

For Units with E-Stop:

 Insert key into e-stop, actuate the e-stop, and remove the key.   

For Combo Units with Chute Block:

 Place the chute block over whichever chute is not being used. 

For Normal Stop Situations:

 Wait 30 seconds for cutting chamber to empty itself before pressing stop button. 

In case of 

emergency

, simply use the stop button or emergency stop. 

Begin feeding material to be shredded into the appropriate feed chute. Reference “capability” section to determine 

appropriate media for each chute. Contact SEM customer service for media not listed in the “capability” section. 

New Operators:

 New operators should be given a minimum two to three hour training period, beginning with a slow feed 

rate. The operator will soon be able to judge how quickly they can feed the shredder.  

Bin Full:

 The bin full indicator will light up when there are approximately 20 lbs. of material in the bin. It is recommended 

to empty this out before and after each shift as well. This will be lower for combo units.  

For Combo Units: Never use both feed chutes at the same time.  

Clearing a Jam 

In the event of a jam, ensure that all personnel are clear of both the input chute and the cutter head. 

Hold the reverse pushbutton for three to five seconds. This will cause the cutters to run backwards for as long as the reverse 

button remains pressed. 

Release the reverse button and the machine will come to a stop. After the machine has completely stopped, press the forward 

button and try to shred material. 

NEVER

 hold the forward button in to clear a jam. Damage to the machine may occur. 

If machine jams again, reverse shredder again, 

de-energize the unit using proper LOTO procedures, 

and manually remove 

the jammed material. Restart machine in the forward direction to resume operation. 

To access the cutting chamber, remove the two screws at the front of the unit on the feed chute cover and lift it up to gain 

access. Will require a 5/32 allen wrench. 

Shut-Down Procedure 

 

Allow cutting chamber to clear all material before shutting down. 

 

Press the stop pushbutton. 

 

If equipped with an e-stop or key-switch, engage the e-stop or turn the key-switch to the “off” position 

 

Turn off the disconnect switch and/or unplug the power cord from the receptacle 

 

Open feed chute cover and inspect cutters for damage 

 

Open the front door and empty the bin/bins (recommended) 

 

Clean any remaining debris from the machine and from the immediate area 

o

 

SEM recommends heavy, cut resistant gloves  

 

 

Содержание 0303

Страница 1: ...US 800 225 9293 508 366 1488 Email service semshred com Fax 508 366 6814 Website www semshred com SEM Model 0303 POP 0044 Rev 0 Created 8 21 18 ECN 00213 This manual covers All Model 0303 configuratio...

Страница 2: ...n this collateral SEM does not warrant that the equipment will work properly in all environments and applications and makes no warranty or representation either implied or expressed with respect to th...

Страница 3: ...RE INTENDED FOR THE DESTRUCTION OF SOLID STATE MEDIA ONLY ATTEMPTING TO SHRED ROTATIONAL DRIVES WILL VOID WARRANTY SHREDDING OF ROTATIONAL HDDs BY USING AN SSD UNIT OR THE COMBO SSD CHUTE COULD CAUSE...

Страница 4: ...tine shredder maintenance including cleaning Never operate this or any other machine while under the influence of drugs alcohol or medications Never wear loose fitting clothing ties or jewelry while i...

Страница 5: ...g and Installation 9 Uncrating 9 General Installation 9 Modular Output Conveyor optional 10 Electrical refer to licensed electrician 11 Electrical Schematics 12 Operation 14 Pre Start Up 14 Start Up 1...

Страница 6: ...M offers three different cutter configurations at various sizes discussed below Hard drive shredders at 1 5 and 0 75 shred widths can shred SSDs but it is not recommended Solid state only shredders at...

Страница 7: ...es Feeding a standard rotational hard disk drive into an SSD unit or the combo SSD chute will jam the machine and could result in permanent damage Unacceptable Media The following materials should nev...

Страница 8: ...0 General Assembly Drawing Shredder Cabinet Collection Bin Access Door Feed Chute Control Panel Top Cover Serial Number Tag Location Back Panel Power Cord Filter Access Panel left side Current Relay P...

Страница 9: ...8 POP 0044 Rev 0 Collection Bins single chute units have one bin PLC Shredding Chamber Electrical Box Forward Contactor Reverse Contactor Overload Current Transformer Motor...

Страница 10: ...lbs Pry bar and hammer Power drill with Phillips head bit Gloves and safety eyewear Strap cutters Uncrating Remove sides of crate hammer and pry bar Cut straps holding Model 0303 strap cutters Remove...

Страница 11: ...that is on the conveyor to secure the conveyor to the shredder Electrical schematic including conveyor outlet available upon request contact SEM customer service ITEM QTY DESCRIPTION ITE M QT Y DESCR...

Страница 12: ...ve into the appropriate chute if it does not take the drive the rotation is wrong o A licensed electrician should be able to fix this by swapping two leads on the plug A customer supplied disconnect s...

Страница 13: ...at upon request 208V 3PH 60Hz 230V 3PH 60Hz 460V 3PH 60Hz 380 415V 3PH 50Hz Detail Unit Voltage Phase Frequency Incoming Power IP 208 3 60 230 3 60 380 415 3 50 460 3 60 Shredder Motor Mot A HP 3 FLA...

Страница 14: ...13 POP 0044 Rev 0...

Страница 15: ...t with the two leftmost buttons removed Start Activates the cutting chamber Reverse Reverses the rotation of the cutting chamber o Must be held down Stop Deactivates the cutting chamber and stops the...

Страница 16: ...t the same time Clearing a Jam In the event of a jam ensure that all personnel are clear of both the input chute and the cutter head Hold the reverse pushbutton for three to five seconds This will cau...

Страница 17: ...r damage and clear air inlet Remove side guards and visually inspect drive components for leaks or damage Replace all guards Empty waste collection bin Weekly cleaning after each 40 hours of operation...

Страница 18: ...filler and drain plugs Wait for oil to drain out change plug seal Clean magnetic drain plug Replace drain plug and refill to proper level using a high grade petroleum based rust and oxidation inhibit...

Страница 19: ...ange version with two knobs Use the knob labelled threshold Warning Overadjustment can cause the overload to trip which will not allow the device to start until the overload is reset The overload will...

Страница 20: ...BAR OUTSIDE SPACER DRIVE SIDE 27 5 34267 SSD CUTTER STYLE 1 9 4 34584 HD TIE BAR SPACER DRIVE SIDE 28 4 34268 SSD CUTTER STYLE 2 10 2 35483 HD TIE BAR SPACER IDLER SIDE 29 6 34269 SSD CUTTER STYLE 3 1...

Страница 21: ...IE BAR OUTSIDE SPACER DRIVE SIDE 27 13 34276 SSD SHAFT SPACER 9 1 34463 SIDE PLATE DRIVE SIDE 28 2 110016 SPUR GEAR 10 1 34462 SIDE PLATE SPUR GEAR SIDE 29 1 34887 DIVIDER SHAFT SPACER 11 1 34582 END...

Страница 22: ...63 SPACER 3 1 N A REDUCER CONSULT FACTORY 13 2 33772 SIDE PLATE 4 1 33615 DRIVE SHAFT 14 1 33772 SIDE PLATE 5 2 33616 DRIVE SHAFT CUTTER 15 2 33625 END PLATE 6 1 33617 IDLE SHAFT CUTTER 16 2 110016 SP...

Страница 23: ...G BLOCK 11 2 33619 75 WEAR BLOCK 3 1 N A REDUCER CONSULT FACTORY 12 3 33617 75 IDLE SHAFT CUTTER 4 1 33615 DRIVE SHAFT 13 4 33616 75 DRIVE SHAFT CUTTER 5 1 33618 IDLER SHAFT 14 5 33616 75 SHAFT HEX SP...

Страница 24: ...RIVE SHAFT 16 4 34269 CUTTER STYLE 3 5 1 33618 IDLER SHAFT 17 13 34276 INSIDE SHAFT SPACER 6 4 111907 BEARING 18 30 34575 INSIDE TIE BAR SPACER 7 1 34449 CUTTERHEAD END PLATE REAR 19 7 34576 REAR COMB...

Страница 25: ...rward or reverse power light is not illuminated Defective contact block on stop button Check block for continuity replace if bad Overload tripping Motor overheating Check motor cooling fan for objects...

Страница 26: ...position good for vehicles 5 iWitness P N iWitness Software and barcode scanning system for easily logging and tracking media Comes with laptop scanner and software Below is a list of spare parts and...

Страница 27: ...366 1488 Toll Free US 800 225 9293 Address 5 Walkup Drive PO Box 1045 Westborough Massachusetts 01581 Follow us on social media Facebook https www facebook com semshred Twitter https twitter com semse...

Отзывы: