11
POP-0044 – Rev. 0
Electrical (refer to licensed electrician)
•
Be sure to follow proper “Lock Out Tag Out” (LOTO) procedures.
•
Power:
This unit is equipped to run 3-phase power, depending on the chosen voltage at purchase.
•
Panels:
All panels contained within this unit carry a rating of IP65.
•
All electrical installation and service must be done by a qualified electrician. Follow all national and local electrical
codes and ordinances.
•
All internal wiring has been factory installed and tested prior to shipping. Electrical installation consists of providing
adequate machine power only.
•
Check building service to ensure correct voltage is available and that the electrical current requirements can be met.
•
Motor Rotation:
Ensure area is clear and turn the key switch on. Check for proper motor rotation.
o
Feed a single drive into the appropriate chute; if it does not take the drive, the rotation is wrong.
o
A licensed electrician should be able to fix this by swapping two leads on the plug.
•
A customer supplied disconnect switch should be mounted on a wall within one to two feet of the device.
•
Electrical installation is complete.
Replace all guards and safety devices.
•
SEM recommends a less than 3% voltage drop for on the receptacle/disconnect for optimal performance. This is critical
on 208V devices.
•
3-phase units are supplied with an open-ended cord - see the voltage/amperage chart below. SEM recommends a
minimum 125% safety factor on the disconnects, and no more than a 3% voltage drop for best performance.
Voltage/Frequency
Full Load Amps (FLA)
[w/ AFS]
Apparent Power kVA
(Line to Line)
Recommended
Disconnect [w/ AFS]
208 Volts/60 Hz
11 [11.9]
4.0 [4.3]
20 Amp [20 Amp]
230 Volts/60 Hz
9.6 [10.5]
3.8 [4.2]
20 Amp [20 Amp]
460 Volts/60 Hz
4.8 [5.7]
3.8 [4.5]
20 Amp [20 Amp]
380 Volts/50 Hz
6.1[7.0]
4.2 [4.9]
20 Amp [20 Amp]
400 Volts/50 Hz
415 Volts/50 Hz
Содержание 0303