background image

 

USER INSTRUCTIONS 

To

 

get

 

the

 

best

 

benefit

 

from

 

your

 

freezer,

 

please

 

read

 

the

 

following

 

instructions

 

carefully

 

and

 

act

 

accordingly.

 

This

 

equipment

 

is

 

a

 

freezer

 

chest

 

that

 

allows

 

you

 

to

 

have

 

stored

 

samples,

 

medical

 

preparations

 

(vaccines,

 

blood

 

plasma,

 

etc.)

 

and

 

other

 

biological

 

products,

 

safely

 

against

 

possible

 

losses.

 

It

 

includes

 

a

 

system

 

based

 

on

 

eutectic

 

gel,

 

which

 

has

 

the

 

property

 

of

 

keeping

 

the

 

temperature

 

below

 ‐

20ºC

 

for

 

a

 

long

 

period

 

of

 

time.

 

1. Environmental protection and disposal 

The

 

packaging

 

is

 

designed

 

to

 

protect

 

the

 

appliance

 

and

 

its

 

components

 

during

 

transportation,

 

and

 

it

 

is

 

made

 

of

 

recyclable

 

materials.

 

 

Please

 

return

 

the

 

packaging

 

to

 

an

 

official

 

collection

 

point

 

for

 

recycling.

 

 

Old

 

appliances

 

contain

 

reusable

 

materials

 

and

 

should

 

not

 

be

 

disposed

 

of

 

together

 

with

 

household

 

refuse.

 

 

Remove

 

the

 

spring

action

 

hinges

 

from

 

the

 

appliance,

 

in

 

order

 

to

 

prevent

 

children

 

from

 

being

 

entrapped

 

in

 

the

 

appliance.

 

 

Ensure

 

that

 

no

 

part

 

of

 

the

 

refrigeration

 

tubing

 

is

 

damaged

 

as

 

the

 

refrigerant

 

in

 

the

 

appliance

 

risks

 

escaping

 

to

 

the

 

environment.

 

 

Information

 

about

 

refrigerant

 

type

 

and

 

amount

 

will

 

be

 

found

 

on

 

the

 

type

 

plate

 

on

 

the

 

rear

 

of

 

the

 

appliance

 

(Fig.

 

1).

 

2. Safety instructions 

 

In

 

order

 

to

 

prevent

 

injuries

 

and

 

/

 

or

 

damage

 

to

 

the

 

appliance,

 

it

 

should

 

be

 

unpacked

 

and

 

set

 

up

 

by

 

min.

 

two

 

people.

 

 

If

 

upon

 

unpacking

 

the

 

appliance

 

is

 

found

 

damaged,

 

do

 

not

 

connect

 

to

 

the

 

mains,

 

but

 

contact

 

the

 

supplier.

 

Interference

 

with

 

or

 

repair

 

to

 

the

 

appliance

 

should

 

only

 

be

 

carried

 

out

 

by

 

authorized

 

personnel,

 

in

 

order

 

to

 

avoid

 

any

 

injuries

 

(Contact

 

the

 

supplier

 

for

 

further

 

information)

 

 

Never

 

put

 

naked

 

flames

 

or

 

other

 

ignition

 

sources

 

inside

 

the

 

appliance.

 

 

Never

 

touch

 

the

 

freezers

 

interior

 

or

 

products

 

in

 

the

 

freezer

 

when

 

the

 

freezer

 

is

 

operating.

 

Use

 

gloves

 

or

 

alike

 

in

 

order

 

to

 

avoid

 

injuries

 

(frostbite).

 

 

Keep

 

the

 

key

 

to

 

the

 

appliance

 

away

 

from

 

the

 

appliance

 

and

 

out

 

of

 

the

 

reach

 

of

 

children.

 

3. Connection to the mains 

 

For

 

safety

 

reasons

 

the

 

appliance

 

must

 

be

 

earthed.

 

If

 

you

 

are

 

in

 

any

 

doubt,

 

please

 

contact

 

an

 

authorized

 

electrician.

 

 

The

 

appliance

 

should

 

be

 

left

 

for

 

5

 

hours

 

before

 

it

 

is

 

connected

 

to

 

the

 

mains.

 

If

 

the

 

appliance

 

is

 

connected

 

before

 

that,

 

there

 

is

 

a

 

risk

 

of

 

damaging

 

the

 

compressor.

 

 

If

 

for

 

any

 

reason

 

the

 

appliance

 

is

 

disconnected

 

from

 

the

 

mains,

 

please

 

wait

 

10

 

minutes

 

before

 

re

connecting.

 

The

 

electronic

 

starting

 

device

 

needs

 

this

 

time

 

to

 

cool

 

down,

 

before

 

a

 

safe

 

re

start

 

can

 

be

 

made.

 

4. Before use 

Before

 

use,

 

the

 

interior

 

of

 

the

 

appliance

 

should

 

be

 

cleaned

 

with

 

a

 

mild

 

soap

 

solution,

 

and

 

wiped

 

off

 

with

 

a

 

Содержание 2000150

Страница 1: ...98 REV 0 07 2020 J P SELECTA s a u Autov a A 2 Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website http www jpselecta es C MARA REFRIGERADO...

Страница 2: ...Dixell controller 4 14 Functions 4 15 Setting the controllers offset value 4 16 Trouble shooting 5 INDEX SAFETY INFORMATIONS 6 USER INSTRUCTIONS 7 1 Environmental protection and disposal 7 2 Safety i...

Страница 3: ...y o explosivos no deben almacenarse en el congelador Todas las unidades deben recibir instrucciones de instalaci n y de funcionamiento Adem s de la instalaci n con los espacios libres las instruccione...

Страница 4: ...to 2 Instrucciones de seguridad Para evitar lesiones y da os al equipo deben desembalarlo y configurarlo m nimo dos personas Si al desembalarlo observa que el equipo est deteriorado no lo conecte a la...

Страница 5: ...iento del congelador El congelador vac o debe estar encendido durante al menos 24 horas antes de cargarlo El congelador no debe cargarse por encima de las paredes interiores que indica el l mite de la...

Страница 6: ...y suelte inmediatamente la tecla SET o espere 5 segundos para mostrar nuevamente el valor de la sonda C mo bloquear y desbloquear el teclado 1 Pulse las teclas Arriba y Abajo simult neamente durante...

Страница 7: ...mbiente es demasiado alta Se ha cargado recientemente el aparato con una gran cantidad de productos calientes La temperatura dentro del equipo es demasiado alta Por favor compruebe si El controlador D...

Страница 8: ...ble gasses and explosives must not be stored in the freezer All units should be provided with installation and operating instructions In addition to the Clearances Installation the instructions should...

Страница 9: ...Fig 1 2 Safety instructions In order to prevent injuries and or damage to the appliance it should be unpacked and set up by min two people If upon unpacking the appliance is found damaged do not conn...

Страница 10: ...eezer The empty freezer should be switched on for at least 24 hours prior to loading of the freezer The freezer should not be loaded above the inside walls which is also the load line limit Please not...

Страница 11: ...than 3 seconds How to change the set point 1 Press the SET key for more than 3 seconds to change the set point value 2 The set point value will be displayed and the LED starts flashing 3 To change the...

Страница 12: ...Dixell controller set to the correct temperature Has an excess amount of ice formed inside the appliance If you have checked the above points and the appliance is still not working as expected please...

Страница 13: ...de una temperatura Opcionalmente la entrada digital puede convertirse en una tercera entrada de sonda La salida HOT KEY permite conectar la unidad por medio del m dulo externo XJ485 CX a una red compa...

Страница 14: ...urante el ciclo continuo se utiliza este set point COn Tiempo compresor ON con fallo de sonda 0 255 min tiempo durante el cual el compresor est operando en caso de fallo de sonda Con COn 0 el compreso...

Страница 15: ...r Realiza un deshielo si las condiciones son adecuadas Despu s del deshielo haya terminado la regulaci n normal se restablecer solo si la entrada digital se deshabilita de otro modo el instrumento deb...

Страница 16: ...inales 7 y 8 120Vac conectar l alimentaci n a los terminales 7 y 8 16 2 XR30C COMPRESOR 20A N C 1 2 3 4 5 6 7 9 10 11 12 Comp Light Alarm Room 8 Hot Key IV probe TTL or X REP output 8 3 A250V 20 8 A25...

Страница 17: ...0 255 min 15 Pr1 nPS N mero activaci nes para la funci n pres stato 0 15 15 Pr2 OdC Control de puerta abierta no FAn CP F C no Pr2 rrd Regulaci n despu s alarma de puerta abierta n Y y Pr2 HES Difere...

Страница 18: ...to display a temperature The digital input can operate as third temperature probe The HOT KEY output allows to connect the unit by means of the external module XJ485 CX to a network line ModBUS RTU co...

Страница 19: ...OFF in case of faulty thermostat probe With COF 0 compressor is always active CH Type of action CL cooling Ht heating DISPLAY CF Temperature measurement unit C Celsius F Fahrenheit WARNING When the me...

Страница 20: ...P can be connected to the instrument trough the HOY KEY connector The X REP output EXCLUDES the serial connection To connect the X REP to the instrument the following connectors must be used CAB 51F 1...

Страница 21: ...delay at start up 0 255 min 0 Pr2 AC Anti short cycle delay 0 50 min 1 Pr1 CCt Continuos cycle duration 0 0 24 0h 0 0 Pr2 CCS Set point for continuous cycle 55 0 150 0 C 67 302 F 3 Pr2 COn Compressor...