Selecta 2000150 Скачать руководство пользователя страница 10

 

dry

 

clean

 

cloth.

 

Never

 

use

 

any

 

kind

 

of

 

solvent

 

or

 

other

 

chemicals

 

5. Setting up the freezer 

The

 

freezer

 

should

 

not

 

be

 

placed

 

where

 

it

 

might

 

be

 

splashed

 

with

 

water,

 

in

 

extreme

 

high

 

humidity

 

or

 

in

 

direct

 

sunlight.

 

Any

 

of

 

these

 

factors

 

may

 

lead

 

to

 

a

 

reduction

 

in

 

performance

 

and

 

shorten

 

the

 

life

 

span

 

of

 

the

 

components.

 

The

 

freezer

 

should

 

be

 

placed

 

on

 

a

 

horizontal

 

level,

 

and

 

should

 

not

 

be

 

placed

 

close

 

to

 

a

 

heating

 

appliance

 

or

 

heating

 

tubes.

  

Allow

 

a

 

minimum

 

of

 

50mm

 

clearance

 

on

 

the

 

side

 

and

 

the

 

back.

 

The

 

side

 

with

 

the

 

ventilation

 

grill

 

should

 

have

 

a

 

clearance

 

of

 

at

 

least

 

100

 

mm

 

in

 

order

 

to

 

allow

 

the

 

heat

 

from

 

the

 

compressor

 

motor

 

to

 

dissipate.

 

Underneath

 

the

 

appliance,

 

these

 

should

 

be

 

a

 

gap

 

of

 

15

 

mm

 

approx.

 

On

 

a

 

soft

 

surface,

 

e.g.

 

carpet,

 

it

 

may

 

be

 

necessary

 

to

 

ensure

 

the

 

correct

 

distance

 

by

 

means

 

of

 

spacers.

 

6. Electrical supply 

The

 

electrical

 

supply

 

should

 

always

 

be

 

in

 

accordance

 

with

 

the

 

rating

 

plate

 

on

 

the

 

back

 

of

 

the

 

freezer.

 

The

 

supply

 

must

 

always

 

be

 

in

 

accordance

 

with

 

the

 

law

 

and

 

regulations

 

regarding

 

electrical

 

safety.

 

If

 

any

 

doubts,

 

contact

 

your

 

supplier.

  

 

7. Starting Up 

In

 

case

 

the

 

compressor

 

does

 

not

 

start

 

when

 

the

 

freezer

 

has

 

been

 

plugged

 

in,

 

the

 

electrical

 

supply

 

may

 

not

 

be

 

in

 

order.

 

Check

 

if

 

there

 

is

 

an

 

electricity

 

supply

 

to

 

the

 

plug

 

or

 

if

 

the

 

fuse

 

is

 

blown.

  

 

8. Operating the freezer 

The

 

empty

 

freezer

 

should

 

be

 

switched

 

on

 

for

 

at

 

least

 

24

 

hours

 

prior

 

to

 

loading

 

of

 

the

 

freezer.

 

The

 

freezer

 

should

 

not

 

be

 

loaded

 

above

 

the

 

inside

 

walls

 

which

 

is

 

also

 

the

 

load

 

line

 

limit.

 

Please

 

note:

 

After

 

the

 

lid

 

has

 

been

 

opened,

 

there

 

will

 

be

 

a

 

vacuum

 

created

 

inside

 

the

 

freezer

 

due

 

to

 

the

 

low

 

temperatures.

 

Wait

 

a

 

few

 

minutes

 

before

 

trying

 

to

 

re

open

 

the

 

lid

 

otherwise

 

the

 

handle

 

could

 

be

 

damaged.

 

The

 

freeze

 

storage

 

system

 

is

 

based

 

on

 

a

 

PCM

 

material,

 

to

 

ensure

 

the

 

correct

 

response

 

keep

 

it

 

freezed

 

for

 

a

 

long

 

time

 

(1

 

week).

 

Take

 

care

 

about

 

your

 

samples

 

before

 

to

 

load

 

in.

 

9. Defrosting 

In

 

order

 

for

 

the

 

freezer

 

to

 

work

 

to

 

its

 

maximum

 

efficiency

 

the

 

cabinet

 

should

 

be

 

defrosted

 

when

 

an

 

approx.

 

2mm

 

thick

 

ice

 

layer

 

has

 

formed

 

inside

 

the

 

cabinet.

 

Keep

 

the

 

freezer

 

off

 

for

 

a

 

long

 

time

 

with

 

the

 

lid

 

open.

 

Never

 

use

 

a

 

sharp

 

metal

 

object,

 

which

 

might

 

will

 

cause

 

damage

 

to

 

the

 

inner

 

liner.

 

The

 

defrosting

 

frequency

 

is

 

determined

 

mainly

 

by

 

two

 

factors

 

the

 

usage

 

pattern

 

(number

 

of

 

lid

 

openings)

 

and

 

the

 

relative

 

humidity.

 

Excess

 

water

 

can

 

be

 

drained

 

out

 

by

 

using

 

the

 

drain

 

water

 

outlet

 

on

 

the

 

front

 

of

 

the

 

freezer.

 

10. Cleaning 

Cleaning

 

should

 

be

 

done

 

when

 

needed.

 

When

 

used

 

in

 

a

 

dirty

 

environment

 

it

 

might

 

be

 

necessary

 

to

 

remove

 

the

 

compressor

 

compartment

 

grill,

 

and

 

clean

 

the

 

compressor

 

compartment

 

eventually

 

with

 

a

 

vacuum

 

cleaner.

 

If

 

the

 

cleaning

 

process

 

is

 

neglected,

 

there

 

is

 

a

 

risk

 

that

 

the

 

performance

 

of

 

the

 

freezer

 

will

 

be

 

effected,

 

and

 

even

 

damage

 

to

 

the

 

compressor

 

could

 

occur

 

due

 

to

 

overheating.

 

Содержание 2000150

Страница 1: ...98 REV 0 07 2020 J P SELECTA s a u Autov a A 2 Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website http www jpselecta es C MARA REFRIGERADO...

Страница 2: ...Dixell controller 4 14 Functions 4 15 Setting the controllers offset value 4 16 Trouble shooting 5 INDEX SAFETY INFORMATIONS 6 USER INSTRUCTIONS 7 1 Environmental protection and disposal 7 2 Safety i...

Страница 3: ...y o explosivos no deben almacenarse en el congelador Todas las unidades deben recibir instrucciones de instalaci n y de funcionamiento Adem s de la instalaci n con los espacios libres las instruccione...

Страница 4: ...to 2 Instrucciones de seguridad Para evitar lesiones y da os al equipo deben desembalarlo y configurarlo m nimo dos personas Si al desembalarlo observa que el equipo est deteriorado no lo conecte a la...

Страница 5: ...iento del congelador El congelador vac o debe estar encendido durante al menos 24 horas antes de cargarlo El congelador no debe cargarse por encima de las paredes interiores que indica el l mite de la...

Страница 6: ...y suelte inmediatamente la tecla SET o espere 5 segundos para mostrar nuevamente el valor de la sonda C mo bloquear y desbloquear el teclado 1 Pulse las teclas Arriba y Abajo simult neamente durante...

Страница 7: ...mbiente es demasiado alta Se ha cargado recientemente el aparato con una gran cantidad de productos calientes La temperatura dentro del equipo es demasiado alta Por favor compruebe si El controlador D...

Страница 8: ...ble gasses and explosives must not be stored in the freezer All units should be provided with installation and operating instructions In addition to the Clearances Installation the instructions should...

Страница 9: ...Fig 1 2 Safety instructions In order to prevent injuries and or damage to the appliance it should be unpacked and set up by min two people If upon unpacking the appliance is found damaged do not conn...

Страница 10: ...eezer The empty freezer should be switched on for at least 24 hours prior to loading of the freezer The freezer should not be loaded above the inside walls which is also the load line limit Please not...

Страница 11: ...than 3 seconds How to change the set point 1 Press the SET key for more than 3 seconds to change the set point value 2 The set point value will be displayed and the LED starts flashing 3 To change the...

Страница 12: ...Dixell controller set to the correct temperature Has an excess amount of ice formed inside the appliance If you have checked the above points and the appliance is still not working as expected please...

Страница 13: ...de una temperatura Opcionalmente la entrada digital puede convertirse en una tercera entrada de sonda La salida HOT KEY permite conectar la unidad por medio del m dulo externo XJ485 CX a una red compa...

Страница 14: ...urante el ciclo continuo se utiliza este set point COn Tiempo compresor ON con fallo de sonda 0 255 min tiempo durante el cual el compresor est operando en caso de fallo de sonda Con COn 0 el compreso...

Страница 15: ...r Realiza un deshielo si las condiciones son adecuadas Despu s del deshielo haya terminado la regulaci n normal se restablecer solo si la entrada digital se deshabilita de otro modo el instrumento deb...

Страница 16: ...inales 7 y 8 120Vac conectar l alimentaci n a los terminales 7 y 8 16 2 XR30C COMPRESOR 20A N C 1 2 3 4 5 6 7 9 10 11 12 Comp Light Alarm Room 8 Hot Key IV probe TTL or X REP output 8 3 A250V 20 8 A25...

Страница 17: ...0 255 min 15 Pr1 nPS N mero activaci nes para la funci n pres stato 0 15 15 Pr2 OdC Control de puerta abierta no FAn CP F C no Pr2 rrd Regulaci n despu s alarma de puerta abierta n Y y Pr2 HES Difere...

Страница 18: ...to display a temperature The digital input can operate as third temperature probe The HOT KEY output allows to connect the unit by means of the external module XJ485 CX to a network line ModBUS RTU co...

Страница 19: ...OFF in case of faulty thermostat probe With COF 0 compressor is always active CH Type of action CL cooling Ht heating DISPLAY CF Temperature measurement unit C Celsius F Fahrenheit WARNING When the me...

Страница 20: ...P can be connected to the instrument trough the HOY KEY connector The X REP output EXCLUDES the serial connection To connect the X REP to the instrument the following connectors must be used CAB 51F 1...

Страница 21: ...delay at start up 0 255 min 0 Pr2 AC Anti short cycle delay 0 50 min 1 Pr1 CCt Continuos cycle duration 0 0 24 0h 0 0 Pr2 CCS Set point for continuous cycle 55 0 150 0 C 67 302 F 3 Pr2 COn Compressor...

Отзывы: