background image

The non-metallic coating is painted on the surface of the product and the non-metallic label is attached on
the surface of the product, electrostatic charge may cause an explosion hazard. Avoid any actions that cause
the generation of electrostatic charge, such as rubbing with a dry cloth on coating surface of the product.

Don’t cover the product with an inflammable material such as cloth or paper nor put anything in the product.
Such a material or thing might cause an explosion or fire.

For outdoor use, waterproof the screw connections and the entries of the terminal box to prevent rainwater
infiltration. For the stanchion type, waterproof the screw connections of the stand pole to prevent rainwater
infiltration. Inadequate waterproofing might cause a fire or electric shock.

Don’t open or loosen any part unless necessary. Confirm that the screws, bolts and the like are fastened
tightly. A loose part might cause an explosion, fall, fire or electric shock.

Prior to maintenance or inspection, be sure to turn off the power and wait at least ten minutes before opening
the enclosure. An explosion, fire or electric shock might result.

If you continue to use the product in an abnormal condition (smoke, odor, etc.), an explosion, fire or electric
shock might result. If you detect an abnormality, immediately turn off the power switch. Confirm that the
abnormal condition has been eliminated and have it repaired by a specialist.
The components once removed for cleaning or maintenance should be replaced properly according to the
instruction manual. An incorrectly placed component might cause an explosion or fall, resulting in an injury or
property damage.

WARNING

When leading the power cable into the product, be sure to follow the technical standards for electrical
equipment and the guide for the explosion protection of factory electrical equipment. Inadequate cable
connection or poor waterproofing might cause an explosion, fire or electric shock.
In grounding work, follow the technical standards for electrical equipment and the guide for the explosion
protection of factory electrical equipment. Inadequate grounding might cause an explosion, fire or electric
shock.

Don’t convert the product.
Conversion might cause fall of the product, an explosion, fire or electric shock.

CAUTION

To ensure brightness and safety, carry out cleaning and inspection periodically. (If the product is using in
explosive dust area, regular dust cleaning must be done but don't clean the surface by air gun. )

If you find a problem, stop using he product and have it repaired by a specialist.

Never touch the lamp and its surroundings while it is on or just after it is turned off.
The lamp and its surroundings are very hot. An accidental touch might burn yourself.

Don’t use the product at a voltage other than the voltage indicated on the nameplate. The voltage variation
should be within ±6% of the rating. Otherwise a damage, fire or electric shock might result.

Don’t use the product at a frequency other than the local power supply frequency (50 or 60 Hz).
A wrong frequency might cause a fire.

The product should be installed by a qualified person.
Installation by an unqualified person is legally prohibited.

Because this product is painted non-metallic coating , please refer to the note below.

・Avoid friction ・No dry cleaning ・Do not mount in areas with flowing, non-conductive products

Содержание WLZAA14021

Страница 1: ...used within an ambient temperature range of 20ºC to 40ºC If the ambient temperature is out of the range an explosion or fire might result Usable in hazardous areas of zone 1 zone 2 zone 21 and zone 22 where there is explosive atmospheres The product should be of the flameproof type suitable for each hazardous area Use of an unsuitable product might cause an explosion or fire For electrical connect...

Страница 2: ... might cause an explosion or fall resulting in an injury or property damage WARNING When leading the power cable into the product be sure to follow the technical standards for electrical equipment and the guide for the explosion protection of factory electrical equipment Inadequate cable connection or poor waterproofing might cause an explosion fire or electric shock In grounding work follow the t...

Страница 3: ... part due to an accident in transit etc Start of Use Performance of the product 1 The electrical characteristics of the product are as follows Assembly and Installation Use The LEDs are turned on by applying the rated voltage to the power line of the product Install the product properly following the instruction manual 1 Attach the lighting fitting on the mounting surface firmly in using M6 bolts ...

Страница 4: ...e 2 After loosen the set screw open the cap in using accessory special tool 3 Remove three connecters Install power wires and earthing wire and set connecters to original position Disconnect connectors In case of changing the inclination Be sure to turn off the power before starting After removing the cap disconnect the connectors Disconnect the cable from the terminal Loosen the cable gland and m...

Страница 5: ... parts No stained insulator Retighten Clean Temperature rise Thermometer Tactile The surface temperature should be not more than 85 C Investigate the cause Turn off the power 1 In cleaning the fitting gently wipe with water or mild detergent Don t use thinner benzene or alkaline detergent Such chemicals might cause discoloration or deterioration in quality and strength resulting in a damage 2 Prio...

Страница 6: ...to the following Plug 20 to 85 Cable gland 20 to 85 Cables 20 C to 85 9 Confirm that the fitting is adequately grounded 10 Prior to maintenance or inspection be sure to turnoff the power 11 Don t use the product in a corrosive gas atmosphere which contains hydrochloric acid high concentration chlorine gas or the like 12 To prevent shortening of the service life avoid turning on the fitting indirec...

Страница 7: ...7 ...