27
K100000000S9 036103 130121
10.2 Menu→Measurements→Comb. analysis
11/12/17 10:00
SET ANALYSIS
►Mode Auto
Fuel
Natural gas
Interval 7 s
Memory 1/5
Status Free
Start
INTERACTIVE OPERATION FUNCTION
Starts the analysis with the selected mode
PARAMETER
DESCRIPTION
Mode
This menu allows the user to choose among 2 different analysis modes: Manual or Auto
Manual
:
In manual mode, the combustion analysis is performed manually by prior
setting the ‘ Fuel ’ parameter.
Then, the manual analysis can start but waiting, at the beginning, at least two
minutes that the shown values are stable; at this moment it is possible to
proceed with the memorization or directly to print depending on the setting
made.
In this mode it is possible to print or save just one combustion analysis
containing all the data necessary to fill in the booklet of the system or plant.
Auto:
In this mode the instrument performs 3 different measures divided by a time
gap defined by the user using the sub parameter ‘ interval ‘. Moreover, it is
possible to select the memory in which is needed to store the analysis and set
the used fuel.
In all modes, the data displayed regarding the pollutants CO / NO / NO
x
can be translated
into normalized values (with reference to the concentration of O
2
previously set in
“configuration => analysis” menu).
Fuel
Allows the choice of the fuel to be used in analysis phase. This data can be changed not only
in this menu, but also in configuration menu.
Interval
ONLY IN ‘AUTO MODE’.
Sets the time interval for the sample acquisition with a value variable from 1 to 900 seconds.
Memory
ONLY IN ‘AUTO MODE’.
Allows to select the memory number where to save the analysis. If the memory is full it is
possible to choose whether to overwrite the values of the analysis formerly acquired.
KEY
FUNCTION
Activate the context keys shown on the
display.
Returns to the previous screen.
Selects the available parameters.
Enters the selected parameter and con-
firms the choice made.
>
>
ESC
OK
>
>
Start