48
K900000000SE 022628A0 071013
Tightness test flow-chart according to standards UNI 7129 and UNI 11137: 2012.
Pressurize the piping and select TEST
with the ' ' key.
Automatically after a few seconds.
Automatically, after 15 minutes.
During stabilization the pipe pressure
P
is displayed
and also its variation
∆
P
1
’
during the last minute.
The stabilization wait time is the one set in the test
configuration menu. Stabilization can be stopped at
any time by pressing ' '.
►New piping
Existing piping
TIGHTNESS TEST
►Start test
Stabilization
UNI 7129 STANDARD
Start test
►Stabilization
UNI 7129 STANDARD
►Wait time
UNI 7129 STANDARD
15 min
Wait time
UNI 7129 STANDARD
15
min
min
min
min
►Start test
Stabilization
UNI 7129 STANDARD
Charge the pipe to
the test pressure
100.00 hPa
UNI 7129 STANDARD
0.06
hPa
UNI 7129 STANDARD
ZERO
TEST
0.00
hPa
UNI 7129 STANDARD
ZERO
ZERO
ZERO
ZERO
TEST
TEST
TEST
TEST
100.00
hPa
UNI 7129 STANDARD
ZERO
TEST
P 100.00hPa
∆P1’ 0.00hPa
Wait time:20.00
OK to proceed
STABILIZATION
P1 100.00hPa
P2 99.99hPa
∆P -0.01hPa
Result:15.00
UNI 7129 STANDARD
WARNING
End the tightness
test
UNI 7129 STANDARD
QUIT
QUIT
QUIT
QUIT
ABORT
ABORT
ABORT
ABORT
WARNING
End the tightness
test
UNI 7129 STANDARD
QUIT
QUIT
QUIT
QUIT
ABORT
ABORT
ABORT
ABORT
P1 100.00hPa
P2 99.99hPa
∆P -0.01hPa
Result: tight
UNI 7129 STANDARD
Model tight
PRINT REPORT
QUIT
Model tight
PRINT REPORT
QUIT
Automatically
►RefO
2
Auto:001
▼
O
2
4.2
٪
CO
2
9.3
٪
λ,n 1.25
Tf 190.1C
Ta 15.4C
∆T 74.7C
Qs 8.6
٪
ηs 91.4
٪
ηt 91.4
٪
CO 146p
NO 40p
SO
2
41p
Wait time
UNI 7129 STANDARD
20
min
min
min
min
1
2
3
4
5
6
7
8