TB MRI(K)3-C 03.02 E
Contents
1 Introduction and Application
2 Characteristics and Features
3 Design
3.1 Connections
3.1.1 Analog
input
circuits
3.1.2 Output
relays
3.1.3 Digital
inputs
3.1.4
Low/High range of the digital Inputs
3.2 Password
3.2.1 Code
jumpers
3.2.2 Password
programming
3.2.3
Function of the output relays
3.3 Front
plates
3.3.1 Indicating
LEDs
3.3.2 Adjusting
LEDs
3.4
Front plates (for ER/XR-relay types)
3.4.1 Indicating
LEDs
3.4.2 Adjusting
LEDs
4 Working principle
4.1 Analog
circuits
4.2 Digital
circuits
4.3 Status
descriptions
4.3.1 „Inactive“
4.3.2
„Reclaim time“ tR
4.3.3 „AR-ready“
4.3.4
„AR-starting“ (dead time)
4.3.5 „AR-cycle“
(auto
reclosing)
4.3.6 „AR-blocked“
4.3.7
„Fast Trip Mode“
4.3.8 „Blocking
mode“
4.3.9
„Activating of AR“
4.3.10 Description of the status transition
4.3.11 AR information inputs
4.4 Functional
sequence
4.4.1 Switching
on
MRIK3-C
4.4.2
Circuit breaker manual closing
4.4.3
Circuit breaker manual open
4.4.4 Starting
AR
4.4.5 Unsuccessful
reclosing
4.4.6 Successful
reclosing
4.4.7 Repeated
reclosing
4.4.8
Supervision of the circuit breaker ready
information
4.4.9 External
blocking
4.4.10 Time sequence diagrams of
MRIK3-C
4.4.11 The unit is programmed for two shots,
successful AR at the second shot
4.4.12 The unit is programmed for two shots,
unsuccessful AR
4.4.13 Manual closing of the circuit breaker to
faulty lines
4.4.14 Unsuccessful
AR
4.5 Earth
fault
protection
4.5.1
Generator stator earth fault protection
4.5.2
System earth fault protection
4.6 Earth-fault
directional
feature
(ER/XR-relay type)
4.7 Control
functions
4.7.1 Introduction
4.7.2
Interlocking / Password for control mode
4.7.3
Operating assignment of C.B. control
4.7.4
Changing the operating assignment
4.7.5
Saving the operating assignment
4.7.6
Remote switching on and off of the C.B.
4.7.7
Switching on or off the C.B. via the front
panel (LCAL)
4.7.8
Handling of the control function
4.7.9
Display for the control functions
4.7.10 LED-indication under normal mode
4.7.11 LED-indication auto reclosing conditions
(AR)
4.8
Requirement on the Main Current
Transformers
5 Operation and Adjustments
5.1
Displayed text for parameter settings
5.2 Setting
procedure
5.3 Parameter
levels
5.4 System
parameters
5.4.1
Presentation of Measuring Values as
Primary Quantities on the Display
(I
prim
Phase)
5.4.2
Display of residual voltage U
E
as primary
quantity (U
prim
/U
sec
)
5.4.3
Voltage transformer connection for resi-
dual voltage measuring (3pha/e-n/1:1)
5.4.4
Operation cycle counter
5.4.5 I
2*
t Operation cycle counter
5.4.6 Rated
-Frequency
5.4.7
Indication of pickup
5.4.8
Parameter Set Changeover Switch (P2)
5.5 Protection
Parameters
5.5.1
Pickup current for phase overcurrent
element
5.5.2
Trip Characteristics for the Phase Over-
current Element (I>)
5.5.3
Tripping Time or Time Factor for the
Phase Overcurrent Element
5.5.4
Fast/Time tripping by switch ON of the
CB for the overcurrent lement
5.5.5
Reset Mode for the Trip Characteristics
in the Phase Current Path
5.5.6
Current setting for high set element
5.5.7
Trip delay for high set element
5.5.8
Fast/Time tripping by switch ON of the
CB for the short ciruit element
5.5.9
Pickup value for residual voltage (U
E
)
(ER/XR-relay types)