89
• Normal Ope
n – used when the input device is normally open status by
default, please reference the input device specification.
If you are unsure of the specification please use the
default setting Normal Open.
• Normal Closed
– use when the input device is normally close status by
default, please reference the input device specification.
INTERVAL
The INTERVAL is the time frame to dictate when the IPcam-SD should start
recording whenever an alarm input event occurs. For example, if an event
occurs at 5:00:00 pm and you have the interval set to 15 seconds, the actual
recording will not take place until 5:00:15 pm.
NOTE:
Please take into consideration that the Interval time will be
subtracted from the “Pre-Record” time frame. The system default setting is
interval 1 second, the earliest the system can start to record on an event. To
extend the event start time to record please set to a higher value.
DELAY
The DELAY (post-record) time frame lets you dictate how much longer the
IPcam-SD should keep recording after its default 10 second (per camera
failure event) recording has expired. For example, if a camera failure event
occurs at 5:00:00 pm and you have the delay time set to 15 seconds, the
actual recording will not stop until 5:00:35 pm (10 second d 15
second delay).
COPY
The COPY button can be used to copy the current configuration on the
screen to the other cameras available through the CMS (when more than one
camera is available).
PASTE
The PASTE button is used to paste the configuration settings that were
copied to the selected camera.
REFRESH
The REFRESH button discards the changes you made to the current settings
and sets them back to the way they were when the configuration window
was first opened.
OK
The OK button saves your changes and exits back the previous screen.
CANCEL
The CANCEL button discards any changes made and exits back to the
previous screen.
• • • •ALARM OUTPUT
The ALARM OUTPUT sub-menu located in the “Alarm” menu option consists
of 5 settings that are used to configure the IPcam-SD’S alarm output port.
These settings are:
• A. Configuration
- operates on the configuration settings that are being
used on for the alarm input.
• B. On -
enables the alarm output port based on a 24hr default settings.