2.
CERTIFICATION LABEL
Note: the certification label is located in the lower right corner under the finishing trim.
TESTED TO: ULC S610 M87
TESTÉ SELON: UL 127 7th ed.
May 16, 1996
LISTED FACTORY BUILT
FIREPLACE
FOYER PRÉFABRIQUÉ
HOMOLOGUÉ
DATE OF MFG
1 2 3 4 5 6 7 8 9 10 11 12
YEAR
2004 05 06 07 08 09 10 11 12
LAVAL-
CLEARANCES TO COMBUSTIBLES
:
SIDE WALL: 24" (610 mm) (FROM DOOR EDGE)
MANTLE:
59" (1422 mm) (ABOVE BASE OF
THE FIREPLACE)
BACK WALL AND FIREPLACE SIDE: 0" (0 mm)
(FROM SPACERS)
CEILLING HEIGHT: 8' (2438 mm) (ABOVE THE
BASE OF FIREPLACE)
CHIMNEY: 2" (51 mm)
DÉGAGEMENTS AUX COMBUSTIBLES
:
MUR LATÉRAL :
24 po. (610 mm) (DE
L'OUVERTURE DE LA PORTE)
LINTEAU :
59 po. (1442 mm) (AU-DESSUS
DE LA BASE DU FOYER)
MUR ARRIÈRE ET CÔTÉ DU FOYER : 0 po.
(0 mm) (DES ESPACEURS)
HAUTEUR PLAFOND : 8' (2438mm)
(AU-DESSUS DE LA BASE DU FOYER)
CHEMINÉE : 2" (51 mm)
FUEL: WOOD ONLY
NON COMBUSTIBLE HEARTH EXTENSION
MUST BE INSTALLED AT FRONT OF UNIT
EXTENDING 18 in (457 mm) AT FRONT AND 6 in.
(152 mm) TO SIDES OF DOOR OPENING.
THIS FIREPLACE HAS NOT BEEN TESTED
WITH UNVENTED GAS LOG SET. TO REDUCE
RISK OF FIRE OR INJURY DO NOT INSTALL AN
UNVENTED GAS LOG SET INTO THE
FIREPLACE.
ELECTRICAL RATING: 115 V, 60 Hz
CAN BE CONNECTED TO A MASONRY
CHIMNEY AS DESCRIBED IN THE INSTALLATION
INSTRUCTIONS.
COMPONENTS USED WITH THE FIREPLACE
MUST BE LISTED. SEE LIST IN THE
INSTALLATION INSTRUCTIONS.
REPLACE GLASS WITH CERAMIC GLASS 5 mm
THICK.
FOR SAFE OPERATION INSTALL IN
ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS.
CAUTION: COMBUSTION AIR OPENING MUST
NOT BE OBSTRUCTED.
DO NOT OVERFIRE THE FIREPLACE.
OPERATE THE FIREPLACE WITH DOORS FULLY
OPEN OR FULLY CLOSED ONLY.
COMBUSTIBLE: BOIS SEULEMENT
UN TABLIER NON COMBUSTIBLE DOIT ÊTRE INSTALLÉ À L'AVANT
DU FOYER EXCÉDANT DE 18 po. (457 mm) À L'AVANT ET 6 po. (152
mm)
DES CÔTÉS DE L'OUVERTURE DES PORTES.
MAINTENIR LES MEUBLES ET AUTRES OBJETS À UNE DISTANCE
SÉCURITAIRE DU FOYER.
ALIMENTATION ÉLECTRIQUE : 115V, 60 Hz.
UTILISER SEULEMENT AVEC UNE CHEMINÉE 10 po. (254 mm)
DE DIAMÈTRE, MODÈLE ASHT+, GASHT, , AC HOMOLOGUÉE.
PEUT ÊTRE RACCORDÉ A UNE CHEMINÉE DE MAÇONNERIE
TEL QUE DÉCRIT DANS LE MANUEL D'INSTALLATION.
LES COMPOSANTES UTILISÉES AVEC LE FOYER DOIVENT ÊTRE
HOMOLOGUÉES. VOIR LA LISTE DANS LE MANUEL D'INSTALLATION.
REMPLACER LA VITRE AVEC UN VERRE CÉRAMIQUE DE 5 mm
D'ÉPAISSEUR.
POUR UNE UTILISATION SÉCURITAIRE, INSTALLER
CONFORMÉMENT AUX DIRECTIVES DU FABRICANT.
ATTENTION : NE PAS OBSTRUER LES ARRIVÉES D'AIR
COMBURANT.
NE PAS FAIRE SURCHAUFFER LE FOYER.
LES PORTES DU FOYER DOIVENT DEMEURER TOTALEMENT
OUVERTES OU TOTALEMENT FERMÉES LORSQUE LE FOYER
FONCTIONNE.
INSTALL WITH MINIMUM
CLEARANCES TO WALL AS
SHOWN IN INCHES
INSTALL AND USE ONLY IN
ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS
AND LOCAL BUILDING CODES.
CHIMNEY TYPE: USE ONLY LISTED
CHIMNEY MODEL GASHT, ASHT+,
, AC, dia. 10 In..
SPECIAL METHODS ARE
REQUIRED WHEN PASSING
THROUGH A WALL OR CEILING.
SEE INSTRUCTIONS AND
BUILDING CODES.
PREVENT CREOSOTE FIRE:
INSPECT CHIMNEY CONNECTOR
AND CHIMNEY FLUE MONTHLY
AND CLEAN IF NECESSARY.
DO NOT OVERFIRE. IF DOME OR
CHIMNEY CONNECTOR GLOWS
YOU ARE OVERFIRING.
KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS A
CONSIDERABLE DISTANCE AWAY
FROM APPLIANCE.
FLOOR PROTECTOR MINIMUM
DISTANCE FROM OPENING IN
INCHES
HEARTH EXTENSION
MATERIAL:
-
1" THICKNESS NON
COMBUSTIBLE MATERIAL
- OR EQUIVALENTS