3.4.4 Optional Fireplace Blower (UZY5)
A heat activated blower is sold as an option. It is designed to be located in the back of the
fireplace and increase the air flow around the firebox. It uses regular 120V and must be
connected to the main electrical circuit by a qualified electrician.
An electrical box must be
installed outside the fireplace.
WARNING: Because of the fireplace size and obstructive air venting, we don‟t
recommend the installation of the blower unless the gravity duct are installed on the
fireplace.
If you wish to adjust the blower speed, an optional variable speed control (VRUW) can be
installed in line with the wiring. Again, use a qualified electrician for installation.
To install the blower,
1-
Remove the refractory bricks and the andiron.
2-
Remove the metal plates covering the bottom and back of the hearth firebox.
3-
Disconnect the main electric cable from the blowers by unplugging its two quick
connectors.
4-
Remove the knock-out in the front right side of the fireplace outer casing.
5-
Install a metallic wire protector and slide the blower main electrical cable from the
outside to the inside of the unit.
6-
Install the two fans in the back of the fireplace through the holes in the back.
Warning: Make sure there are no contact between the fans and the door slider.
7-
Reconnect the main cable quick connectors and stick (magnet) the heat activate
switch under the right side of the firebox.
Using aluminums tape, make sure no
wiring touch the firebox by taping it to the bottom of the fireplace panel.
8-
Install all plates, bricks and andiron.
9-
Connect the blower plug into the electrical box located outside the fireplace
Figure 15
Figure 14