Symptom 1:
LED’s on the ID Exit Panel are off and the system does not alarm
Potential causes and corrective actions
:
Power switch on the ID Exit Panel is in the OFF position.
Improper output voltage: Verify output voltage is approximately 12 - 15VDC.
Verify that the AC outlet power supply is connected and has an output of 110-120VAC.
The problem may be in the ID Exit Panel. Replace the ID Exit Panel.
Symptom 2:
The ID Exit Panel will not reset when the code is entered
Potential causes and corrective actions
:
Incorrect reset code is being entered into the keypad.
Check for bent pins on the Remote Keypad.
Initialize ID Exit Panel programming and try the default reset codes.
The problem may be in the ID Exit Panel. Replace the ID Exit Panel.
Symptom 3:
The ID Exit Panel has no range with transmitter(s) present. (The signal LED is NOT flashing
or solid with no transmitter in range.)
Potential causes and corrective actions
:
Verify that the transmitter in use is not expired or damaged.
Verify that the same transmitter works at another exit location.
Verify that the faceplate of the ID Exit Panel is not damaged.
The range setting may not be adjusted properly. Adjust the range and retest. (Refer to Antenna Range
Adjustment in
Section 9
of this manual.)
The problem may be in the ID Exit Panel. Replace the ID Exit Panel.
Symptom 4:
The ID Exit Panel will not alarm when a monitored transmitter goes through the door.
Potential causes and corrective actions
:
Check the magnetic door contact for proper operation: Open loop when the door is open and closed
loop when the door is closed.
Verify that the transmitter in use is not expired or damaged
The range setting may not be adjusted properly. Adjust the range and retest. (Refer to Antenna Range
Adjustment in
Section 9
of this manual.)
RF interference may be affecting performance. Locate the source of the interference and remove or
filter it.
The Push Button input may be shorted. Disconnect any wires connected to the Push Button input and
retest.
Symptom 5:
The ID Exit Panel has a flickering or solid yellow signal LED when no transmitter is present.
Potential causes and corrective actions
:
RF interference may be affecting performance. Locate the source of the interference and remove or
filter it.
Verify that no other transmitters are within adjusted range of door location.
Verify all unapplied transmitters are stored in appropriate metal containers.
Verify that ferrites were installed. (Refer to
Appendix B
of this manual for proper placement of
ferrites).
SECTION 12
TROUBLESHOOTING
Содержание KinderGUARD ID
Страница 8: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 8...
Страница 9: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 9...
Страница 10: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 10...
Страница 75: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 75...
Страница 77: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 77...
Страница 78: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 78...
Страница 81: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 81...