Doc. No.: A05280692 Rev. AE ECO: 13200 Date: 11/04/2019
51
Programming the STAT ID Exit Panel
NOTE: The PM mode must be disabled to make any programming
changes to the ID Exit Panel. Refer to PM Programming in this section
of the manual.
NOTE: All programming is stored in non-volatile memory. This means
that if the panel loses power, the programming will remain in memory.
Reset Escort Codes
Each ID Exit Panel offers three separate four digit codes for escorting transmitters legally through a protected doorway
or hallway, or resetting an alarm condition created by the presence of a transmitter while the exit door is open or hallway
perimeter is breached. These three codes are referred to as the Primary, Secondary, and Tertiary. The Primary and
Tertiary codes allow for resetting alarm conditions and escorting transmitters through protected areas when the Advanced
Security Mode is not used (refer to programming the Advanced Security Mode for more operation details of that feature).
The Secondary code allows for resetting, escorting, and programming in all conditions. This code allows transmitters to
be escorted through a protected area while Advanced Security Mode is active.
Primary Code
(any three digits proceeded by *).
Factory Default
*234
To change the Primary code, follow the three listed steps without pausing for greater than one second between
keystrokes.
1.
Enter
*567
or currently programmed Secondary code
2.
Enter
*9876543210#
3.
Enter new three digit code.
One confirmation beep = Change Accepted
Secondary Code
(any three digits preceded by *)
Factory Default
*567
To change the Secondary code, follow the three listed steps without pausing for greater than one second
between keystrokes.
Once the Secondary code is changed this new number becomes the new
programming code.
1. Enter
*567
or currently programmed Secondary code
2.
Enter
*9876543211#
3.
Enter new three digit code.
Two confirmation beeps = Change Accepted
NOTE: To Default Secondary code only
Enter *309*9876543212
Tertiary Code
(any three digits proceeded by *).
Factory Default
*751
To change the Tertiary code, follow the three listed steps without pausing for greater than one second between
keystrokes.
1.
Enter
*567
or currently programmed Secondary code
2.
Enter
*9876543212#
3.
Enter new three digit code.
SECTION 10
PROGRAMMING INSTRUCTIONS
Содержание KinderGUARD ID
Страница 8: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 8...
Страница 9: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 9...
Страница 10: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 10...
Страница 75: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 75...
Страница 77: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 77...
Страница 78: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 78...
Страница 81: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 81...