Doc. No.: A05280692 Rev. AE ECO: 13200 Date: 11/04/2019
57
Loiter Alarm
This feature, when programmed and enabled, allows the ID Exit Panel to create a unique audible alarm indicating a
transmitter is in proximity of a monitored door for too long. If the transmitter were to leave the monitored area after the
alarm sounds, the alarm would reset automatically without staff intervention.
Loiter Alarm
Factory Default
Disabled
Enable Default
60 sec.
To
enable
loiter alarm feature follow the three listed steps without pausing for greater than one second
between keystrokes.
1.
Enter
*567
or currently programmed secondary code
2.
Enter
*9876543218#999
Four confirmation beeps = change accepted
To
disable
loiter alarm feature follow the three listed steps without pausing for greater than one second
between keystrokes.
1.
Enter
*567
currently programmed secondary code
2.
Enter
*9876543218#909
Three confirmation beeps = change accepted
To
change
the time of loiter alarm feature in seconds, follow the three listed steps without pausing for greater
than one second between keystrokes. Acceptable range of values: 15 seconds “015” 15 minutes “900”
1.
Enter
*567
or currently programmed secondary code
2.
Enter
*9876543218#XXX
(where “XXX” = time in seconds; example -30 sec. = “030”, 3 min. = “180”)
Two confirmation beeps = change accepted
One confirmation beep = change not accepted
Advanced Security Mode
In Advanced Security Mode the Primary Reset Code (*234 or equivalent) and Tertiary Reset Code (*751 or equivalent)
will not allow the escort of a monitored resident. The Primary Reset Code may still be used to reset an alarm condition.
If a Push Button is used in Advanced Security Mode, it will not allow access while a monitored resident is within the
detection range. An audible alarm will sound while the Push Button is pressed and a monitored resident is nearby. In the
absence of a monitored resident the Push Button and Primary Reset Code will work as usual. Enabling the Advanced
Security Mode feature has no affect on the Secondary Reset Codes (*567 or equivalent) operation.
Advanced Security Mode
Factory
Default
Enabled
To
enable
the advanced security mode, follow the three listed steps without pausing for greater than one
second between keystrokes.
1.
Enter
*567
or currently programmed Secondary code
2.
Enter
*9876543215#999
Four confirmation beeps = change accepted
To
disable
the advanced security mode, follow the three listed steps without pausing for greater than one
second between keystrokes.
1.
Enter
*567
or currently programmed Secondary code
2.
Enter
*9876543215#909
Three confirmation beeps = change accepted
SECTION 10 PROGRAMMING INSTRUCTIONS
Содержание KinderGUARD ID
Страница 8: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 8...
Страница 9: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 9...
Страница 10: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 10...
Страница 75: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 75...
Страница 77: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 77...
Страница 78: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 78...
Страница 81: ...Doc No A05280692 Rev AE ECO 13200 Date 11 04 2019 81...