Programming the Egress Delay/Warning/Alarm (continued):
NOTE: When the egress button is programmed to hold for a delay time before the door is
released, it is important to put a sign near the egress button to notify users of the
delay time.
Delay Time:
•
0
– No delay time (default): Output #1 operates immediately when the egress button is
pressed.
•
1
to
99
– Egress button delay time: The delay time can be set from 1 to 99 seconds. This
tells the keypad how long to wait after the egress button is pressed before activating output #1.
Examples:
1.
Momentary mode
– Press the egress button, and the keypad will beep for 5 seconds before
output #1 activates:
90 2 5 #
2. Hold button to activate
– Press and hold the egress button for 10 seconds, and the keypad will
beep for those 10 seconds before output #1 activates:
90 5 10 #
3. Return to default setting – Press the egress button to activate output #1 with no beeping or
delay:
90 1 0 #
NOTE
: For safety and to avoid confusion, when a delay or a press-and-hold delay is
programmed, please post a notice near the egress button, such as: “Press and hold the
button for 5 seconds or until the door is unlocked.”