TAMPER
N.C.
O/P
2
N.O.
DU OUT
EG IN
(–) GND
DOOR SENS.
O/P
1
INHIB
INT LOCK
(+) (–)
12~24 V
AC/DC
OUTPUT
1
N.C. | COM | N.O.
FULL AUTO
BACK-LIT
BUZZER
+
+
+
+
Connection terminals
Backlit jumper
Connection terminals
Stand-Alone Door Lock:
In this application, the keypad is connected to a single door lock and an egress pushbutton.
8
ENFORCER Vandal Resistant Flush-Mount Access Control Keypad
SECO-LARM U.S.A., Inc.
Connection Terminals
Tamper N.C.
Tamper switch output, N.C. contact,
max. 50mA@24VDC.
Connect to the N.C. 24-hour protection zone of
an alarm if needed.
12~24 VAC/VDC
Connect to a 12~24 VAC/VDC power supply.
Observe polarity
.
Output 1 N.C.
NO/NC/COM, relay output,
max. 1A@30VDC
Output 1 COM
Output 1 N.O.
Output 2 N.O.
Transistor ground output, max. 100mA@24VDC.
Duress Output
Transistor ground output, max. 100mA@24VDC.
Triggers a silent alarm or other device when the
user enters a duress code.
Egress Input
N.O. Pushbutton contact to ground. Press button to activate Output #1
Ground (-)
Common ground output.
Door Sensor
Connect to an optional N.C. sensor such as a magnetic contact to monitor if a door is open or
closed. Connect to ground (–) if not used.
Output 1 Inhibit
Output #1 inhibitor. N.O. input, connect to Interlock Control of second keypad if needed so that if
one keypad is used to open a door, the other is temporarily disabled.
Interlock Control
Interlock Control. N.O. input, connect to Output #1 Inhibit of second keypad if needed so that if one
keypad is used to open a door, the other is temporarily disabled.
Wiring Diagram:
Jumper Settings
Jumper
Position Description
Backlit
Full
Dim backlit during standby. Full backlit for 10 seconds after any button press.
Auto
No backlit during standby. Full backlit for 10 seconds after any button press.
Sample Applications: