27
ENFORCER Vandal Resistant Flush-Mount Access Control Keypad
SECO-LARM U.S.A., Inc.
Programming the Egress Delay/Warning (continued):
•
4
Hold contact with no warning – Press and hold the egress button for the programmed delay
time until the door is open. This prevents accidental opening of the door.
•
5
Hold contact with warning beep – Press and hold the egress button for the programmed
delay time until the door is open. The keypad will beep during the delay time before letting the
door open, to warn that someone is preparing to exit the protected area.
NOTE: When the egress button is programmed to hold for a delay time before the door is
released, it is important to put a sign near the egress button to notify users of the
delay time.
Delay Time:
•
0
– No delay time (default): Output #1 operates immediately when the egress button
is pressed.
•
1
to
99
– Egress button delay time: The delay time can be set from 1 to 99 seconds. This
tells the keypad how long to wait after the egress button is pressed before activating output #1.
Examples:
1. Momentary mode
– Press the egress button, and the keypad will beep for 5 seconds before
output #1 activates:
90 2 5 #
2.
Hold button to activate – Press and hold the egress button for 10 seconds, and the keypad will
beep for those 10 seconds before output #1 activates:
90 5 10 #
3. Return to default setting
– Press the egress button to activate output #1 with no beeping
or delay:
90 1 0 #
NOTE
: For safety and to avoid confusion, when a delay or a press-and-hold delay is
programmed, please post a notice near the egress button, such as: “Press and hold the
button for 5 seconds or until the door is unlocked.”