28
Optional IR Remote Control
T/C
T/C
Read
Lux
Flash Code
Intensity
Battery Status
Test / Configure
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
The IR programmer is used to communicate with Sealite lighting products that have an IR sensor fitted.
The remote control is used for the following functions:
• Flash Code
: Read the current flash code, configure a new flash code.
• Lamp Intensity
:
Read the current lamp intensity, configure a new intensity level.
• Ambient Light Thresholds
:
Read the current light thresholds, configure new
ambient light thresholds.
• Perform a battery health check
.
On receiving a valid key signal from the IR Programmer, the light will flash once.
The user should wait until the light responds to each keypress before pressing
another key. If there is no response to the keypress after 3 seconds, it has not been
detected by the light and the key can be pressed again.
If an invalid key is detected, the light will flash quickly 5 times. In this case, the
command will have to be restarted.
IR Controller Functions
Test Mode / Configure
Pressing the T/C button up to 5 seconds places the light in Test Mode. The light will flash once in response
to the T/C button being pressed and then turn off.
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
Normal Operation
The light will return to normal operation once it has not detected a valid key press for 30 seconds. The
light will flash once to indicate it is returning to normal operation.
Read
Pressing the Read followed by one of the configuration keys shall cause the light to flash the configured
value.
Example Key Sequences:
The light flashes the ‘IR Remote’ number belonging to the currently set Flash Code.
Refer to the Flash Code tables to match the ‘IR Remote’ flash number to the Flash
Code.
The light flashes the current intensity setting: 1 flash for 25%, 2 for 50%, 3 for 75%
and 4 for 100%.
The light flashes the current battery status.
The light flashes the sunset level in Lux, followed by a 2 second gap, followed by
the sunrise level. Levels are in the range of 1 to 5.
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2
T/C
T/C
R
L
FC
I
B
3
4
5
6
7
8
9
0
1
2