background image

INSTRUCTION MANUAL

VARTON LED  LUMINAIRES

Operation and Safety

 

Luminaire should be used in accordance with the rules in force 

on the territory of luminaire’s usage; 

 

Installation, dismantling and maintenance of VARTON® electrical 

products should be carried out when power is switched-off;

 

To avoid accidents it is strictly prohibited:

 

To carry out installation, dismantling and maintenance of products 

when power is switched-on;

 

VARTON® LED lightning equipment and component parts must not 

have any mechanical damage while being installed;

 

During installation follow the instructions - incorrect installation 

may damage the product;

 

VARTON® LED lightning equipment can be used only with original 

VARTON® component parts;

 

It is recommended that a person with special access for relevant 

works carries out the installation of VARTON® electrical products 
in accordance with the instructions enclosed;

 

In order to improve reliability and extend the service life it is 

recommended to periodically inspect electrical products being in use 
to detect possible contamination, mechanical damage and to assess 
performance;

 

In order to avoid electrical shock, the luminaire must be grounded. 

Use a green or yellow network connection wire of 220V.

Certification and Disposal

 

All VARTON products are manufactured in accordance with direc-

tives: Low voltage directive 2006/95/EC (ex-73/23/EEC) and Electro-
magnetic compatibility directive 2004/108/EC; 

 

VARTON® LED lightning equipment is environment friendly, does 

not require special conditions and permits for disposal, does not fall 
into hazardous waste category.

Transportation and Storage Conditions

 

Transportation of luminaries should be carried out by rail and road, 

as well as in heated pressurized compartments of an aircraft, in accor-
dance with rules applicable to each type of transport;

 

Transit container should be protected from atmosphere precipi-

tation while being transported. The alignment and securing of cargo 
in vehicles should ensure that position of cargo during transportation;

 

Packed luminaries should be stored under the cover or in rooms 

where temperature and humidity fluctuations are insignificantly 
different from fluctuations outdoors. Temperature of surrounding 
air can vary from - 60 °C to + 60 °C and have relative humidity of 75% 
at a temperature of 15 °C (annual average). It is necessary to exclude 
the presence of acid and alkaline impurities in the air that can affect 
luminaires. The environment should not be explosive, should not 
contain oil mist, metallic dust, conductive dust, corrosive gases and 
concentrated vapors causing corrosion.

Warranty

 

Out-of-service electrical products can be replaced if the invoice 

and this instruction or the sales slip and this instruction or/and 
warranty certificate are given;

 

If the service conditions were met, the warranty period is 3 years, 

starting from the date of the purchase, but not more than 40 months 
starting from the manufacturing date;

 

In the absence of a shop stamp or a trading organization stamp, 

warranty period is counted from the manufacturing date of VARTON® 
LED luminaire;

 

The luminaire matches technical specifications and is recognized 

serviceable.

Necessary conditions for electrical products VARTON® provi-

sion of guarantee

 

Out-of-service VARTON® products can only be replaced if there 

is no visible physical damage;

 

Products are replaced if a correctly filled-in warranty card (with 

the name of the product, the date, the purchase location, the signature 
of a seller, the stamp on it) and a cash receipt or a properly document-
ed passport and an invoice of the company, where the product was 
bought, are presented;

 

Goods that have visible physical damage are not subject to replace-

ment;

 

Products that fail to function after contact with foreign objects, 

liquids and other materials and substances that are not intended 
to come into contact with electrical products are not subject 
to replacement; 

 

Products that fail to function as a result of force major, like fire, 

flood, etc. are not subject to replacement.

For details check link 

http://varton.eu/downloads/technical-characteristics.pdf

Address of the manufacturer: 

LLC TMC VARTON - Scientific-Production Center VARTON, 

Russia, 01831, Tula Region, Bogoroditsk town, 30 Years of 

Victory Str., Building 1a. 

Technical support service: [email protected]

Address of the Importer:

Varton Lighting S.r.l. 

Piazzale Biancamano 8 - 20121 Milano (MI), Italia

+39 0011 583 5315

[email protected]

Manufacturing date
Controller    
Packer 

Warning! Before installation or replacement 

switch off the power!

Technical characteristics

 

Input voltage AC 220-240V, AC/DC 36V;

 

Lifetime 50 000 hours;

 

Color rendering index R

a

 

> 80;

 

Ambient temperature - 40 °C + 45 °C;

 

Surface/suspending mounting;

 

Safety class I.

Installation

 

The luminaire can be mounted onto flat surface of normally-com-

bustible material as well as on suspensions;   

 

VARTON luminaire’s installation needs to be fulfilled in a way so as 

to provide a secure fixation  and convenient layout diagram;

 

When mounting onto supporting surface you need to drill insertion 

holes on the supporting surface 640-770 mm/ 230-370mm, then  bolt 
on metal clamps (supplied);

 

Suspended mounting: fix the cable (not supplied) on metal clamps 

by means of bolts. Snap metal clamps on the housing; 

 

Dirty diffuser requires cleaning by means of soft cloth without 

aggressive detergents’ application.

VARTON LED Industrial Luminaires STRONG IP65

Installation

 

Plug in a luminaire through a connecter or a socket protected from 

moisture and dust. Ensure that power output goes in accordance with 
an identification mark. Safety class should be at least IP65. Mind 
wires color-marking (brown - phase L, blue - neutral N, green / yellow 
- grounding);

 

Install the luminaire onto a console with diameter ranging from 40 

to 48 mm; 

 

Align the luminaire parallel to the console and tighten it by two 

screws M8 (supplied) with force of at least 8 N * m. 

VARTON LED Street Luminaires URAN XS IP65

Technical characteristics

Installation 

 

Plug in a luminaire through a connecter or a socket protected from 

moisture and dust. Ensure that power output goes in accordance with 
an identification mark. Safety class should be at least IP65. Mind 
wires color-marking (brown — phase L, blue — neutral N, green / yellow 
— grounding);

 

Install the luminaire onto a console with diameter ranging from 40 

to 55 mm;

 

Align the luminaire parallel to the console and tighten it by two 

screws M10 (supplied) with force of at least 8 N * m.

Varton LED BULKHEAD Vandalproof Luminaires IP65 (220х90х50/185x70mm)

Technical characteristics       

 

Input voltage AC 220-240V, AC/DC 24-36V;

 

Lifetime 50 000 hours;

 

Color temperature 3000K;

 

Color rendering index R

> 80;

 

Ambient Temperature – 25 °C to + 40 °C;

 

Safety class II.

Installation 

Picture 1

 

The luminaire can be installed directly on a flat surface made of 

normally ignitable material;

 

Take the diffuser off, take out the LED module and the set of 

fasteners;

 

Installation of LED luminaire VARTON® should be carried out to 

provide secure fixation and comfortable layout of lamps (see Picture 1):

 

While installing the luminaire on the bearing surface, drill align-

ment holes on the surface. Then punch holes in a luminaire body. Fix 
the luminaire onto the bearing surface, seal attaching spots with 
rubber washers (supplied separately);

 

Insert network wires into the luminaire body through rubber 

gasket and connect them to the terminal blocks on the LED module in 
accordance with polarity;

 

Fix the LED module on the luminaire body steadily through mount-

ing sockets;

 

Fix the diffuser on the luminaire body;

 

It is recommended to wipe contaminated diffuser with a cloth with-

out abrasive cleansers.

 

Input voltage AC220-240V, 50Hz;

 

Lifetime 50 000 hours;

 

Color temperature 5000K;

 

Color rendering index R

a

 

> 75 for 54W, R

a

 

> 80 for 38W;

 

Ambient temperature - 40 °C  + 45 °C;

 

Safety class I.

VARTON LED Commercial Luminaires T-LINE, G-LINE, MARKET-LLINE, MERCURY

Technical characteristics 

 

Input voltage AC 220-240V, 50Hz;

 

Lifetime 50 000 hours;

 

Color rendering index R

a

 > 80;

 

Several modifications available: universal, 

surface, recessed and suspended mounting;

 

Ambient Tempe 1 °C + 40 °C;

 

Safety class I.

Installation

 

When using VARTON® LED luminaires Mercury, Market-Line, T-Line 

for surface-mounted, it is fixed on the mounting surface with fasten-
ers (self-drilling screws are not supplied in the kit);

 

When using VARTON® LED luminaire for suspension employment, 

suspension set should be availed of;

 

While assembling two or more luminaires, they should be connect-

ed to each other in-line in accordance with polarity, for this purpose 
the connecting shackle should be used; G-Line luminaires are designed 
for installation in plasterboard ceiling structures by means of clamp-
ing fixtures;

 

A single luminaire or a line (construction) of luminaires are closed 

with back covers with G-Line luminaires back covers are used with / 
without a feed-through plate;

 

Connect it to the power network in accordance with indicated 

polarity;

 

 

T-Line luminaire with dimensions 585x70x90 is suitable for creat-

ing light-lines and constructions together with similar models of T-Line 
luminaires with dimensions 1174x70x90, power of 36W. And it is not 
suitable for luminaires with power of 18W;

 

Mercury luminaires IP23 with dimensions 1500*66*8mm is suit-

able for installanion as a continuous “light line“.