66
Additional Test if Message 6 GLA is required
NOTE: Only complete this section if the AIS AtoN has been configured with Message 6 schedule.
28. Adjust input voltage back to 12.6VDC and turn the Light ON.
29. Message 6 GLA Light ON format as shown in Figure 10.
30. Make sure LIGHT ON message is displayed as shown in Figure 10.
31. Turn the Light Off.
32. Message 6 GLA Light Off as shown in Figure 11.
33. Make sure LIGHT OFF message is displayed as shown in Figure 11.
34. Create Alarm condition by setting input voltage to 11VDC.
35. Message 6 GLA ALARM as shown in Figure 12.
36. Make sure ALARM message is displayed as shown in Figure 12.
37. Adjust input voltage back to 12.6VDC and turn the Light ON.
38. Sealite Message Light ON format as shown in Figure 13.
39. Make sure ‘Night’ message is displayed and Status Flags is (0x28) as shown in Figure 13.
40. Turn the Light Off.
41. Sealite Message Light Off as shown in Figure 14.
42. Make sure ‘Night’ message is NOT displayed and Status Flags is (0x08) as shown in Figure 14.
43. Create Alarm condition by setting input voltage to 11VDC.