156 Product Manual - Disc Drive SCSI-2/SCSI-3 Interface (Vol. 2; Ver. 2), Rev. E
_____________________________________________________________________________________
Rigid Disc Drive Geometry Parameters
The Rigid Disc Drive Geometry Parameters Page implementation is defined in Table 5.2.1-25. This table
summarizes the function and defines the default value.
Table 5.2.1-25. Rigid Disc Drive Geometry Parameters
PAGE DESCRIPTOR HEADER
Bit
7 6
5
4
3
2
1
0
Byte(s)
0 PS
Page Code 04h
1[1]
0
0
0
0
1
0
0
1
Page Length (16h)
RIGID DISC DRIVE GEOMETRY PARAMETERS
2
Number of Cylinders (MSB)
DEFAULT
[2]
CHANGEABLE
[8]
3
Number of Cylinders
DEFAULT
CHANGEABLE
[8]
4
Number of Cylinders (LSB)
DEFAULT
[2]
CHANGEABLE
[8]
5
Number of Heads
DEFAULT
[3]
CHANGEABLE
[8]
6,7,8
Starting Cylinder - Write Precomp
DEFAULT
[4]
CHANGEABLE
[8]
9,10,11
Starting Cylinder-Reduced Write Current
DEFAULT
[4]
CHANGEABLE
[8]
12,13
Drive Step Rate
DEFAULT
[4]
CHANGEABLE
[8]
14,15,16
Landing Zone Cylinder
DEFAULT
[4]
CHANGEABLE
[8]