27
Control unit SWING 2 with PALM administration
• Visualisation and modification of the following parameters:
• Working times
• Leaf delay
• Partial opening time
• 2 n. maintenance cycles adjustment
• Antisqueezing sensibility SAFETY GATE
• PhotoStop
• PhotoClose
• PushOpen (
excludes the pushover during opening phase)
PALM FUNCTIONS
SWING 2
ALARMS INDICATION TABLE
The flashes sequence,spaced with a pause, is showed on the flashing lamp (for about 20 seconds).
Flashes number
1
3
Kind of alarm
Photocell
Encoder
Flashes number
4
5
Kind of alarm
Stop
Photocell selftst
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
REV 07 - 05/2009
CN3
CN2
RL1
RL2
CN4
RL3
F1
F2
P1
P2
Rv1
Rv2
Rv3
CN1
U1
U2
DIP
J1
L
ED5
L
ED6
L
ED7
L
ED8
L
ED9
LED10
LED1
1
L
ED1
L
ED2
L
ED3
L
ED4
LED12
LED13
LED14
LED15
LED16
TRIMMER ADJUSTMENTS
MOTOR TORQUE ADJUSTMENT
This trimmer allows to adjust the thrust force of the motor reducer. This kind of adjustment is required for operators
without mechanical / hydraulic device for power limitation. The adjustment must be executed so that there is no
crushing danger for people or objects and in any case in accordance with the law in force on the matter.
SLOWDOWN TIME ADJUSTMENT / LEAF DELAY IN WORKING TIMES MODE WITH TRIMMER
This trimmer has a double functionality depending on the selected working mode. In working times selflearning mode
it allows to adjust the length of slowdown time. In working times manual adjusting mode (DIP 8 to ON position) this
trimmer manages the leaf delay.
PAUSE TIME ADJUSTMENT
This trimmer allows the linear adjustment of pause time from 0 to 120 sec. (If you rotate it completely clockwise,
you can adjust the working logics setting it in half-automatics).
ENCODER SENSITIVITY ADJUSTMENT / WORKING TIMES WITH TRIMMER
This trimmer has a double functionality depending on the selected working mode. In working times selflearning mode
it allows to adjust the encoder sensitivity, In working times manual adjusting mode (DIP 8 to ON position), this trimmer
manages the opening and closing time of the automation.
Note: The Encoder must be set following the laws in force. The maximum sensitivity is obtained with the
trimmer Rv4 completely in clockwise position.
Rv4
Rv3
Rv1
Rv2
Rv1
+
-
NOTE:
ROTATING THE
TRIMMER
CLOCKWISE
THE TIMES / VALUES
INCREASE
Rv2
Rv4
Rv3