GENERAL SAFETY INFORMATION 

An  appliance  shall  be  provided  with  an  instruction  manual.  The  instruction  manual  shall  give  instructions  for  the 
installation, operation, and user maintenance of the appliance.
The installation instructions shall specify the need for a grounding-type receptacle for connection to the supply and 
shall stress the importance of proper grounding.
The installation instructions shall inform the installer that permanent wiring is to be employed as required by local 
codes, and instructions for conversion to permanent wiring shall be supplied.

Information shall be supplied with a gate operator for:

a) The required installation and adjustment of all devices and systems to effect the primary and secondary protection 
against entrapment (where included with the operator).
b)  The  intended  connections  for  all  devices  and  systems  to  effect  the  primary  and  secondary  protection  against 
entrapment. The information shall be supplied in the instruction manual, wiring diagrams, separate instructions, or the 
equivalent.

Vehicular gate operators (or systems)

A vehicular gate operator shall be provided with the information in the instruction manual that defines the different 
vehicular gate operator Class categories and give examples of each usage. The manual shall also indicate the use for 
which the particular unit is intended as defined in Glossary, Section 3. The installation instructions for vehicular gate 
operators shall include information on the Types of gate for which the gate operator is intended.

A gate operator shall be provided with the specific instructions describing all user adjustments required for proper 
operation of the gate. Detailed instructions shall be provided regarding user adjustment of any clutch or pressure relief 
adjustments provided. The instructions shall also indicate the need for periodic checking and adjustment by a qualified 
technician of the control mechanism for force, speed, and sensitivity.

Instructions for the installation, adjustment, and wiring of external controls and devices serving as required protection 
against entrapment shall be provided with the operator when such controls are shipped with the operator.

Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions 
or as a separate document. The following instructions or the equivalent shall be supplied where applicable:

IMPORTANT INSTALLATION INSTRUCTIONS

a) Install the gate operator only when:

1) The operator is appropriate for the construction of the gate and the usage Class of the gate,
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 

(1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings 
anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position,

3) All exposed pinch points are eliminated or guarded, and
4) Guarding is supplied for exposed rollers.

b) The  operator  is  intended  for  installation  only  on  gates  used  for  vehicles.  Pedestrians  must  be  supplied  with  a 
separate access opening. The partial access opening shall be designed to promote pedestrian usage. Locate the gate 
such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

c) The  gate  must  be  installed  in  a  location  so  that  enough  clearance  is  supplied  between  the  gate  and  adjacent 
structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access 
areas.

d) The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do 
not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.

e) The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving and 
AWAY FROM THE GATE PATH PERIMETER.

f) Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and 
where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or 
easily accessible controls shall have a security feature to prevent unauthorized use.

g) The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not 
cause the operator to start.

h) A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible

International registered trademark n. 2.777.971

Содержание SUPER FULL TANK 500 G6 120V

Страница 1: ...it 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com REV 02 11 2018 International registered tradema...

Страница 2: ...danger 8 Do not allow children to play or stay within the path of the moving gate 9 Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary...

Страница 3: ...ng intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where...

Страница 4: ...es on not assessable further risks SEA USA Inc in its relentless aim to improve the products is allowed to make whatsoever adjustment without giving notice This doesn t oblige SEA to up grade the past...

Страница 5: ...to move toward a rigid objact closer than 16 inches 406mm are not required to be provided with a means of entrapment protection B1 and B2 means of entrapment protection MUST be MONITORED HORIZONTAL S...

Страница 6: ...the whole movement of the leaf PRECAUTIONS SEA motors have been created for the automation of gates used by vehicles only Be aware to avoid the crossing of the gate path because it is very dangerous f...

Страница 7: ...feet or installations in windy places or in case of closed paneled gates SEArecommends the use of the electric lock on operators without block SB moreover the exclusion of electronic slowdown is recom...

Страница 8: ...8 Clevis Attachment Front bracket Shaft Cover End cover Shaft Rear attachment Breather screw Pin rear attachment short Brass Pin long Oil fill in cover By pass valves Fig 4...

Страница 9: ...cells 11 Warning notice TYPE OF INSTALLATION It is possible to install the Super FullTank with opening inside Fig 6 I n s t a l l t h e operator always i n s i d e t h e p r o p e r t y inside Outside...

Страница 10: ...3 39 8 07 8 46 7 87 8 27 7 68 7 68 7 48 7 28 6 69 7 09 6 50 6 30 6 69 5 91 5 51 5 12 3 15 4 72 3 35 4 92 3 94 5 51 5 71 4 72 6 30 4 92 6 50 6 69 5 51 7 09 7 48 7 87 110 90 110 90 105 90 90 102 90 102...

Страница 11: ...If you have to make a n i c h e o b s e r v e t h e dimensions shown in Fig 8 RELEASE MOUNTING Remove the transporting plate as shown in Fig 9 Mount the release as shown in Fig 10 a d b 70 87 2 56 2 5...

Страница 12: ...nd clevis attachment must be done by the simple pressure of the hands Attention Do not incline the hydraulic operator further than the allowed angle of the oscillating bracket 1 risks the possible bra...

Страница 13: ...t in the closed position execute the following operations 1 Release the operator 2 Pull out completely the chromate shaft and push it back in 0 4 inches 3 Attach the shaft to the front bracket Fig 14...

Страница 14: ...ASE 3 W 4 5 MOTOR HEATING DETECTOR CONTACT NC 6 GROUND YELLOW GREEN GV 1 2 3 4 5 6 Fig 19 ATTENTION It is obligatory to remove the breather screw at the end of the installation BREATHER SCREW Unscrew...

Страница 15: ...s e i n p g O Grey Yellow INSTALLATION OF THE CHROME PLATED SHAFT COVER TORQUE ADJUSTMENT by pass valves Grey Yellow Adjust the opening and closing forces of the gate so that the diagram of the force...

Страница 16: ...sured with the rod inserted into the actuator and the oil level must be at the distributor level Fig 25 OIL LEVEL DISTRIBUTOR LEVEL DISTRIBUTOR PHOTOCELLS TRANSMITTER KEY SWITCH RADIO RECEIVER FLASHIN...

Страница 17: ...Check the release system functionality Check and grease the fixation pivots Check the integrity of the connecting cables Check the good status of all the apparatus which are subject to efforts back fi...

Страница 18: ...ONSIBLE FOR ANY DAMAGE OR INJURY CAUSED BYIMPROPER USE OF THIS PRODUCT SEA reserves the right to do changes or variations that may be necessary to its products with no obligation to notice Fig 28 RISK...

Страница 19: ...ust contact SEAfor instructions WARRANTY for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Elect...

Страница 20: ...850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com International registered tradema...