background image

5. The End of Type E. 

Type E (audible alarm) devices can no longer be used for entrapment protection. This change 

was made because the Type E device is really a warning device, not an entrapment-protection device. Also, all gate 
operator  classes  are  now  required  to  have  an  audio  alarm  that  sounds  when  two  successive  obstructions  are 
encountered via a contact-type system.

6. Access Control Location for Emergency Use. 

An exception has been added in the manufacturer’s instructional 

requirements for the location of controls that operate the gate.
The instructional requirements state that these controls must be at least 6' away from any moving part of the gate. In the 
new exception, “Emergency access controls only accessible by authorized personnel (e.g., fire, police, EMS) may be 
placed at any location in the line-of-sight of the gate.”

7. Barrier-Arm Operator Exception. 

An exception has changed for barrier-arm gate operators requiring entrapment 

protection. The previous exception stated that a barrier-arm operator did not require entrapment protection if the arm 
did not move toward a rigid object closer than 2'. The distance has been reduced to 16" so it more closely aligns with the 
industry-defined entrapment protection provisions in ASTM F2200.

8. Gate Operator Class II and Class III Definitions. 

The definitions for installation classes for gate operators were 

modified. Class II now includes commercial locations 

accessible 

to the general public. Class III was refined to specify 

industrial locations 

not accessible 

to the general public. These changes, while seemingly minor, may affect which gate 

operator is suitable for a particular installation location.

UL 325 ED. 6th ENTRAPMENT PROTECTION REQUIREMENTS

This vehicular gate operator must be installed with at least two independent entrapment protection 

means as specified in the table below.

International registered trademark n. 2.777.971

VERITICAL BARRIER NOTE: 
Barrier gate operators (arm) that is not intended to move toward a rigid objact closer than 16 inches (406mm) 
are not required to be provided with a means of entrapment protection

 *

 B1 and B2 means of entrapment protection MUST be MONITORED

HORIZONTAL SLIDE

VERTICAL LIFT - VERTICAL PIVOT

ENTRAPMENT 

PROTECTION 

TYPES

TYPE A

TYPE B1

TYPE B2

TYPE C

Inherent entrapment protection system

Non-contact sensors such as photoelectric sensors or equivalents

Contact sensors such as edge sensors or equivalent devices

Inherent force limiting, inherent adjustable clutch or inherent pressure relief device

The same type of device shall not be used for both entrapment protection means. Use of a single device to cover both 
the opening and closing directions  is in accordance with the requirement; however, a single device is not required to 
cover both directions. Tice installer is required to install entrapment protection devices in each entrapment zone

TYPE D

Actuating device requiring constant pressure to maintain opening or closing motion of the gate

SWING

VERTICAL BARRIER (ARM)

A , B1*, B2*  or  D

A , B1*, B2*, C   or  D

GATE OPERATOR CATEGORY

Effective January, 12 2016

VEHICULAR GATE OPERATOR CLASSES

Residential Vehicular Gate Operator-Class I: 

A vehicular gate operator (or system) intended for use in garages or 

parking areas associated with a residence of one-to-four single families

Commercial/General Access Vehicular Gate Operator-Class II: 

A vehicular gate operator (or system) intended for 

use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, 
garages, retail store, or other buildings accessible by or servicing the general public

Industrial/Limited Access Vehicular Gate Operator–Class III: 

A vehicular gate operator (or system) intended for 

use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or 
intended to service the general public

Restricted Access Vehicular Gate Operator–Class IV: 

A vehicular gate operator (or system) intended for use in an 

industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to 
service the general public

Содержание SUPER FULL TANK 500 G6 120V

Страница 1: ...it 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com REV 02 11 2018 International registered tradema...

Страница 2: ...danger 8 Do not allow children to play or stay within the path of the moving gate 9 Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary...

Страница 3: ...ng intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where...

Страница 4: ...es on not assessable further risks SEA USA Inc in its relentless aim to improve the products is allowed to make whatsoever adjustment without giving notice This doesn t oblige SEA to up grade the past...

Страница 5: ...to move toward a rigid objact closer than 16 inches 406mm are not required to be provided with a means of entrapment protection B1 and B2 means of entrapment protection MUST be MONITORED HORIZONTAL S...

Страница 6: ...the whole movement of the leaf PRECAUTIONS SEA motors have been created for the automation of gates used by vehicles only Be aware to avoid the crossing of the gate path because it is very dangerous f...

Страница 7: ...feet or installations in windy places or in case of closed paneled gates SEArecommends the use of the electric lock on operators without block SB moreover the exclusion of electronic slowdown is recom...

Страница 8: ...8 Clevis Attachment Front bracket Shaft Cover End cover Shaft Rear attachment Breather screw Pin rear attachment short Brass Pin long Oil fill in cover By pass valves Fig 4...

Страница 9: ...cells 11 Warning notice TYPE OF INSTALLATION It is possible to install the Super FullTank with opening inside Fig 6 I n s t a l l t h e operator always i n s i d e t h e p r o p e r t y inside Outside...

Страница 10: ...3 39 8 07 8 46 7 87 8 27 7 68 7 68 7 48 7 28 6 69 7 09 6 50 6 30 6 69 5 91 5 51 5 12 3 15 4 72 3 35 4 92 3 94 5 51 5 71 4 72 6 30 4 92 6 50 6 69 5 51 7 09 7 48 7 87 110 90 110 90 105 90 90 102 90 102...

Страница 11: ...If you have to make a n i c h e o b s e r v e t h e dimensions shown in Fig 8 RELEASE MOUNTING Remove the transporting plate as shown in Fig 9 Mount the release as shown in Fig 10 a d b 70 87 2 56 2 5...

Страница 12: ...nd clevis attachment must be done by the simple pressure of the hands Attention Do not incline the hydraulic operator further than the allowed angle of the oscillating bracket 1 risks the possible bra...

Страница 13: ...t in the closed position execute the following operations 1 Release the operator 2 Pull out completely the chromate shaft and push it back in 0 4 inches 3 Attach the shaft to the front bracket Fig 14...

Страница 14: ...ASE 3 W 4 5 MOTOR HEATING DETECTOR CONTACT NC 6 GROUND YELLOW GREEN GV 1 2 3 4 5 6 Fig 19 ATTENTION It is obligatory to remove the breather screw at the end of the installation BREATHER SCREW Unscrew...

Страница 15: ...s e i n p g O Grey Yellow INSTALLATION OF THE CHROME PLATED SHAFT COVER TORQUE ADJUSTMENT by pass valves Grey Yellow Adjust the opening and closing forces of the gate so that the diagram of the force...

Страница 16: ...sured with the rod inserted into the actuator and the oil level must be at the distributor level Fig 25 OIL LEVEL DISTRIBUTOR LEVEL DISTRIBUTOR PHOTOCELLS TRANSMITTER KEY SWITCH RADIO RECEIVER FLASHIN...

Страница 17: ...Check the release system functionality Check and grease the fixation pivots Check the integrity of the connecting cables Check the good status of all the apparatus which are subject to efforts back fi...

Страница 18: ...ONSIBLE FOR ANY DAMAGE OR INJURY CAUSED BYIMPROPER USE OF THIS PRODUCT SEA reserves the right to do changes or variations that may be necessary to its products with no obligation to notice Fig 28 RISK...

Страница 19: ...ust contact SEAfor instructions WARRANTY for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Elect...

Страница 20: ...850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com International registered tradema...

Отзывы: