Maintenance & Troubleshooting
DAC-2202 Antenna Control Unit
8-8
8.9.
Communication Port Settings
Number
Description
1
The
IP Address
field displays the Static Internet Protocol address value currently stored in the
Comm IF module (Flash). To change the IP address to match an existing LAN info structure, type
in the desired value and click on the
SUBMIT
button. If the parameter change causes desirable
operation click on the
SAVE
button to store value to memory. This address must conform to the
nnn.nnn.nnn.nnn
format where
nnn
is a number between 0 and 255.
2
The
Net Mask
field displays the Subnet Mask address value currently stored in the Comm IF
module. To change the Subnet to match an existing LAN info structure, type in the desired value
and click on the
SUBMIT
button. If the parameter change causes desirable operation click on the
SAVE
button to store value to Flash. This address must conform to the
nnn.nnn.nnn.nnn
format
where
nnn
is a number between 0 and 255.
3
The
Gateway
field displays the Static Gateway Internet Protocol address value currently stored in
the Comm IF module. To change the Gateway IP address to match an existing LAN info structure,
type in the desired value and click on the
SUBMIT
button. If the parameter change causes
desirable operation click on the
SAVE
button to store value to Flash. This address must conform
to the
nnn.nnn.nnn.nnn
format where
nnn
is a number between 0 and 255.
4
The
TCP Port 0
field displays the Transmission Control Protocol Port 0 value currently stored in
the Comm IF Module. To change the Port value to match an existing LAN info structure, type in
the desired value and click on the
SUBMIT
button. If the parameter change causes desirable
operation click on the
SAVE
button to store value to Flash. This address must conform to the
nnnn
format where
nnnn
is a number between 0 and 65535.
5
The
TCP Port 1
field displays the Transmission Control Protocol Port 1 value currently stored in
the Comm IF Module. To change the Port value to match an existing LAN info structure, type in
the desired value and click on the
SUBMIT
button. If the parameter change causes desirable
operation click on the
SAVE
button to store value to Flash. This address must conform to the
nnnn
format where
nnnn
is a number between 0 and 65535.
6
The
OpenAMIP Port
field displays the Open Antenna-Modem Interface Protocol port value.
This port is specifically used to communicate with an “Open AMIP” compatible satellite modem
and should not be changed from the factory default.
7
The
UDP Port
displays the User Datagram Protocol Port value stored in the Comm IF Module.
This port is specifically used to perform software upgrades to the Comm IF Module and should
NOT be changed.
Содержание DAC-2202
Страница 8: ...Introduction DAC 2202 Antenna Control Unit 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 32: ...Installation DAC 2202 Antenna Control Unit 4 6 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...Functional Testing DAC 2202 Antenna Control Unit 6 4 This Page Intentionally Left Blank ...
Страница 106: ...Technical Specifications DAC 2202 Antenna Control Unit 9 6 This Page Intentionally Left Blank ...
Страница 108: ...Drawings DAC 2202 Antenna Control Unit 10 2 This Page Intentionally Left Blank ...
Страница 113: ......
Страница 114: ......
Страница 115: ......