Press and HOLD both Setup keys for 6 seconds to enter
Setup Mode - AUTO TRIM.
Press both Setup keys momentarily to enter Setup
Mode SAVE NEW PARAMETERS.
Use the LEFT arrow key to start Auto Trim, if the display is not
LOCKED. When Auto Trim is completed press ENTER to write the
calculated values to EL and AZ TRIM.
To
Execute
To
EXIT
SETUP
AUTO TRIM
OR
Set to the desired EL TRIM value. Decrement below zero for negative
values.
To
Execute
To
EXIT
SETUP
EL TRIM 0000
OR
Set to the desired AZ TRIM value. Decrement below zero for negative
values.
To
Execute
To
EXIT
SETUP
AZ TRIM 0000
OR
Set to the desired number of AGC counts, above the noise floor, that
you want Threshold to be set to.
To
Execute
To
EXIT
SETUP
AUTO THRES 0100
OR
This parameter should always be set to the default value for the
antenna model & band.
To
Execute
To
EXIT
SETUP
EL STEP SIZE 0000
OR
This parameter should always be set to the default value for the
antenna model & band.
To
Execute
To
EXIT
SETUP
AZ STEP SIZE 0000
OR
This parameter should always be set to 0000.
To
Execute
To
EXIT
SETUP
STEP INTEGRAL 0000
OR
This parameter should be set to 15 for Ku-Band antennas and 30 for C-
Band antennas.
To
Execute
To
EXIT
SETUP
SEARCH INC 0015
OR
Set to the Search Limit value for the desired search pattern.
To
Execute
To
EXIT
SETUP
SEARCH LIMIT 0100
OR
Set to the desired Search Delay (in seconds).
To
Execute
To
EXIT
SETUP
SEARCH DELAY 0030
OR
Set Sweep Increment for the desired search pattern.
To
Execute
To
EXIT
SETUP
SWEEP INC 0047
OR
Set to the desired System Type value (refer to the setup information,
especially for modem functionality).
To
Execute
To
EXIT
SETUP
SYSTEM TYPE 0007
OR
Set to the appropriate Gyro Type value for the Gyro Compass signal
being used for Heading input to the system.
To
Execute
To
EXIT
SETUP
GYRO TYPE 0002
OR
Set to default value for the 5 VDC servo driven dipole used only on the
xx97-1 TVRO feed. Set to 0000 for all other systems.
To
Execute
To
EXIT
SETUP
5V SCALE 0060
OR
Standard default settings are 2 for Vertical Transmit Polarity and 4 for
Horizontal Transmit Polarity.
To
Execute
To
EXIT
SETUP
TX Polarity 0002
OR
Set this parameter to display the appropriate band selections for your
model antenna, the band(s) of operation and the type of LNB(s)
installed.
To
Execute
To
EXIT
SETUP
TRACK DISP 0000
OR
To
EXIT
SETUP
OR
Press the RIGHT arrow and then press the ENTER key to save the
parameters. “Parameters Saved” will be displayed.
To
Execute
To
EXIT
SETUP
SAVE NEW PARAMETERS
OR
To
EXIT
SETUP
OR
This parameter is used to issue engineering level commands to the
PCU, under the direction of the Service department ONLY.
To
Execute
To
EXIT
REMOTE COMMAND
@0000
OR
This parameter displays results for monitor commands issued in the
Remote Commands menu. This is for technician use only.
To
Execute
To
EXIT
REMOTE MONITOR
OR
This parameter toggles the ON/OFF state of Dishscan. This is for
technician use only.
To
Execute
To
EXIT
REMOTE
DISHSCAN OFF
OR
This parameter toggles the ON/OFF state of Satellite Reference mode.
This is for technician use only.
To
Execute
To
EXIT
REMOTE
SAT REF OFF
OR
This parameter is used to compensate for tilt of the antenna. This is
for technician use only.
To
Execute
To
EXIT
REMOTE TILT
OR
This parameter toggles the ON/OFF state of Balance Mode, used when
balancing the antenna. This is for technician use only.
To
Execute
REMOTE BALANCE
OR
Press the RIGHT arrow and then press the ENTER key to save the
parameters. “Parameters Saved” will be displayed.
To
Execute
To
EXIT
REMOTE PARAMETERS
This parameter is used to calibrate the rotational position of the feed
relative to the horizon.
To
Execute
To
EXIT
SETUP
POL OFFSET 0040
OR
This parameter should be set to the default value for the antenna
model.
To
Execute
To
EXIT
SETUP
POL SCALE 0090
OR
Set to the CCW relative position of the first blockage zone.
To
Execute
To
EXIT
SETUP
AZ LIMIT 1 0000
OR
Set to the CW relative position of the first blockage zone.
To
Execute
To
EXIT
SETUP
AZ LIMIT 2 0000
OR
Set to the elevation angle of the top of the first blockage zone.
To
Execute
To
EXIT
SETUP
EL LIMIT 12 0090
OR
Set to the CCW relative position of the second blockage zone.
To
Execute
To
EXIT
SETUP
AZ LIMIT 3 0000
OR
Set to the CW relative position of the second blockage zone.
To
Execute
To
EXIT
SETUP
AZ LIMIT 4 0000
OR
Set to the elevation angle of the top of the second blockage zone.
To
Execute
To
EXIT
SETUP
EL LIMIT 34 0090
OR
Set to the CCW relative position of the third blockage zone.
To
Execute
To
EXIT
SETUP
AZ LIMIT 5 0000
OR
Set to the CW relative position of the third blockage zone.
To
Execute
To
EXIT
SETUP
AZ LIMIT 6 0000
OR
Set to the elevation angle of the top of the third blockage zone.
To
Execute
To
EXIT
SETUP
EL LIMIT 56 0090
OR
To
EXIT
SETUP
OR
OR
This parameter should be set to 72 for automatic polarization control.
To
Execute
To
EXIT
SETUP
POLANG TYPE 0072
OR
Set to optimize 5 VDC servo driven dipole used only on the xx97-1
TVRO feed. Set to 0000 for all other systems.
To
Execute
To
EXIT
SETUP
5V OFFSET 0020
Содержание DAC-2202
Страница 8: ...Introduction DAC 2202 Antenna Control Unit 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 32: ...Installation DAC 2202 Antenna Control Unit 4 6 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...Functional Testing DAC 2202 Antenna Control Unit 6 4 This Page Intentionally Left Blank ...
Страница 106: ...Technical Specifications DAC 2202 Antenna Control Unit 9 6 This Page Intentionally Left Blank ...
Страница 108: ...Drawings DAC 2202 Antenna Control Unit 10 2 This Page Intentionally Left Blank ...
Страница 113: ......
Страница 114: ......
Страница 115: ......