DAC-2202 Antenna Control Unit
Maintenance & Troubleshooting
8-5
IP
is the ACU IP address
(Factory Default 192.168.30.195)
NM
is the ACU Subnet Mask
(Factory Default 255.255.255.0)
GW
is the ACU Gateway
(Factory Default 192.168.30.1)
TCP 0
is the first of two available TCP/IP Port’s
(Factory Default 2000)
TCP 1
is second of two available TCP/IP Port’s
(Factory Default is 2001)
UDP
is the Comm IF PCB Software Upload port
(Factory Default 3000)
M&C (C)
is the M&C RS232 Port C (J3) Baud Rate
(Factory Default 9600)
NMEA B
is the NMEA RS232 Port B (J2) Baud Rate
(Factory Default 4800)
NMEA A
is the NMEA RS232 Port A (J2)Baud Rate
(Factory Default 4800)
8.
To change Communication Settings
Type “[Control Codennn<cr>”. That’s left bracket,
control code alpha/numeric digit, parameter, <carriage
return> (No Spaces).
Example: Change ACU IP address to 192.168.30.195
type: “[I192.168.30.195
տ
”
Example: Change J2 NMEA Port B Baud Rate to 9600
type: “[B9600
տ
”
9.
To save parameters to Flash (Comm IF PCB)
Type “[W
↵
”.
That’s Left Bracket, Capital “W”,
<carriage return>(No Spaces). Verify “Done” is
displayed after Saving Comm parameters.
**Do not turn power off to ACU until finished**
10.
To reboot Comm IF software Type “[Z
↵
”.
That’s Left Bracket, Capital “Z”, <carriage return> (No
Spaces). Verify “Comm IF Ver x.xx Port M&C (C)” is
displayed.
Содержание DAC-2202
Страница 8: ...Introduction DAC 2202 Antenna Control Unit 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 32: ...Installation DAC 2202 Antenna Control Unit 4 6 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...Functional Testing DAC 2202 Antenna Control Unit 6 4 This Page Intentionally Left Blank ...
Страница 106: ...Technical Specifications DAC 2202 Antenna Control Unit 9 6 This Page Intentionally Left Blank ...
Страница 108: ...Drawings DAC 2202 Antenna Control Unit 10 2 This Page Intentionally Left Blank ...
Страница 113: ......
Страница 114: ......
Страница 115: ......