DAC-2202 Antenna Control Unit
Diagnostic M&C Software Installation & Use
7-11
ProgTerm will then upload the file to the ACU, PCU,
and CommIF module.
Under the Tools Menu Select “ACU Tools>ACU Param
Save” to commit ACU Setup and ACU Tracking
Parameters to NVRAM.
Under the Tools Menu Select “COMM IF
Tools>COMM IF Param Save” to commit the COMM
IF Parameters to NVRAM.
Under the Tools Menu Select “PCU Tools>PCU Param
Save” to commit PCU Setup Parameters to NVRAM.
7.8.
TCP/IP Port Security
DAC2202/2302 Antenna Control Units installed with COMMIF Ver 1.12 or later software versions installed give the
user the ability to require authentication for the TCP 0 and/or, TCP 1 port(s) to allow remote access to the system. It
also gives you the ability to change the factory default username and password required for login access on the
internal HTML Page. The following procedure may only be done via the M&C port (Serial Based Instance of ProgTerm).
Under the COMMIF Tools Menu, select the COMM IF
Param Dump Option or type
[?
.
This will display all of the communication port
settings. Verify that the port in which you wish to
enable authentication on is “Enabled”. If not, first
follow the “Enabling/Disabling M&C Ports” procedure.
Содержание DAC-2202
Страница 8: ...Introduction DAC 2202 Antenna Control Unit 1 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 32: ...Installation DAC 2202 Antenna Control Unit 4 6 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...Functional Testing DAC 2202 Antenna Control Unit 6 4 This Page Intentionally Left Blank ...
Страница 106: ...Technical Specifications DAC 2202 Antenna Control Unit 9 6 This Page Intentionally Left Blank ...
Страница 108: ...Drawings DAC 2202 Antenna Control Unit 10 2 This Page Intentionally Left Blank ...
Страница 113: ......
Страница 114: ......
Страница 115: ......