9711-92 Ku-Band TXRX
Installation Troubleshooting
17-5
Home switch (flag) verification (Unlimited Az
systems only)
DISPV (Ref)
Stabilization
Remote Tilt Verification
DISPV (Ref)
Targeting
Stabilization
Level cage/Level PCB alignment Verification
(sensor alignment)
DISPV (Ref)
Targeting
Stabilization
Rate Sensor Output Verification
DISPW (Rate)
Stabilization
Level and CL fine balance Verification
DISPTC (Drive)
Stabilization
AZ Friction Torque Test
DISPTC (Drive)
Stabilization
DishScan® Drive/Phase
DishScan® XY
Tracking
Stabilization
17.3.4.
Antenna Loop Error Monitoring
The DacRemP
DISPIVC
graph chart provides a means for monitoring the accumulated velocity errors of the
antenna for diagnostic purposes. If this error is excessive, it indicates external forces are acting on the
antenna. These forces may be the result of but not restricted to static imbalance, excessive bearing friction,
cable binding, or wind loading. If these forces cause the antenna to mis-point by more than 0.5° from the
desired position the PCU will flag a “Stab Limit” error.
•
To view the position error, select the
graph chart.
•
This chart displays sensed axis errors via three traces, CL (Cross Level), LV (Elevation), and AZ
(Azimuth), at a fixed 0.05
º
/ vertical division.
•
The normal trace average will plots its display
±
3 divisions from the red reference line. Any
trace line average plotted above this is of concern and troubleshooting required. The example
below shows the forces exerted onto the antenna as a resultant of DishScan® Drive. The
example below shows the results of various forces put upon antenna.
Содержание 9711-92
Страница 3: ......
Страница 10: ...Table of Contents x 22 2 9711 GENERAL DRAWINGS 22 1 This Page Intentionally Left Blank ...
Страница 22: ...Site Survey 9711 92 Ku Band TXRX 2 8 This Page Intentionally Left Blank ...
Страница 62: ...Basic Setup of the ACU 9711 92 Ku Band TXRX 4 4 This Page Intentionally Left Blank ...
Страница 64: ...Setup Ships Gyro Compass 9711 92 Ku Band TXRX 5 2 This Page Intentionally Left Blank ...
Страница 66: ...Setup Band Select 9711 92 Ku Band TXRX 6 2 This Page Intentionally Left Blank ...
Страница 72: ...Setup Home Flag Offset 9711 92 Ku Band TXRX 8 4 This Page Intentionally Left Blank ...
Страница 80: ...Setup Searching 9711 92 Ku Band TXRX 10 6 This Page Intentionally Left Blank ...
Страница 92: ...Setup Modem Connections Setup and Test 9711 92 Ku Band TXRX 12 8 This Page Intentionally Left Blank ...
Страница 100: ...Antenna Specific Operation 9711 92 Ku Band TXRX 15 4 This Page Intentionally Left Blank ...
Страница 104: ...Functional Testing 9711 92 Ku Band TXRX 16 4 This Page Intentionally Left Blank ...
Страница 120: ...Installation Troubleshooting 9711 92 Ku Band TXRX 17 16 This Page Intentionally Left Blank ...
Страница 142: ...Maintenance 9711 92 Ku Band TXRX 18 22 This Page Intentionally Left Blank ...
Страница 158: ...9711 92 Technical Specifications 9711 92 Ku Band TXRX 21 10 This Page Intentionally Left Blank ...
Страница 160: ...Drawings 9711 92 Ku Band TXRX 22 2 This Page Intentionally Left Blank ...
Страница 166: ......
Страница 167: ......
Страница 168: ......
Страница 191: ......
Страница 192: ......
Страница 194: ......
Страница 196: ......