EMS (Engine Management
System)
EMS (Engine Management System) is an electronic system with CAN communication (Controller Area Network)
for diesel engine control. The system has been developed by Volvo Penta and includes fuel control and diagnostic
function.
Input signals
The control module receives input signals about the
engines operating conditions and other things from
the following components:
- coolant temperature sensor
- charge pressure/charge temperature sensor
- crankcase pressure sensor
- position sensor, camshaft
- speed sensor, flywheel
- coolant level sensor
- oil level and temperature sensor
- oil pressure sensor
- fuel pressure sensor
- water in fuel indicator
- exhaust temperature sensor (TWD1643GE)
Output signals
Based on the input signals the control module controls
the following components:
- unit injectors
- starter motor
- main relay
- pre-heating relay
- wastegate (TWD1643GE, TAD1650VE)
- cold start valve (TWD1643GE)
- valve mechanism, internal EGR (TAD1650VE,
TAD1650/51GE)
Information from the sensors provides exact informa-
tion about current operation conditions and allows the
processor in the control unit to calculate the correct
fuel injection volume and timing, check engine status
etc.
Diagnostic function
The task of the diagnostic function is to discover and
localize any malfunctions in the EMS system, to pro-
tect the engine and to ensure operation in the event
of serious malfunction.
If a malfunction is discovered, this is announced by
warning lamps, a flashing diagnostic lamp or in plain
language on the instrument panel, depending on the
equipment used. If a fault code is obtained as a flash-
ing code or in plain language, this is used for guidance
in any fault tracing. Fault codes can also be read by
Volvo’s VODIA tool at authorized Volvo Penta work-
shops.
If there is a serious malfunction, the engine will be
shut down altogether, or the control unit will reduce
the power delivered (depending on application). Once
again, a fault code is set for guidance in any fault trac-
ing.
Fuel control
The engine fuel requirement is analyzed up to 100
times per second. The amount of fuel injected into the
engine and the injection advance are fully electroni-
cally controlled, via fuel valves in the unit injectors.
This means that the engine always receives the cor-
rect volume of fuel in all operating conditions, which
offers lower fuel consumption, minimal exhaust emis-
sions etc.
Presentation
10
7748681 12-2011
138/297
Содержание R570U
Страница 1: ...User and maintenance manual for generating sets R570U 33504081501NE_1_1 ...
Страница 15: ...Alternator Cabinet Figure 1 3 Examples of identification plates 13 297 ...
Страница 18: ...Sockets voltage 208 120V 16 297 ...
Страница 32: ...Figure 4 3 Braking transmission Figure 4 4 Cross bar fitting Figure 4 5 Tandem bearing fitting 30 297 ...
Страница 125: ...9 Appendix 9 1 Appendix A Engine user and maintenance manual 123 297 ...
Страница 126: ...124 297 ...
Страница 128: ...126 297 ...
Страница 129: ...OPERATOR S MANUAL Generating set and industrial engines 16 liter EMS 2 127 297 ...
Страница 159: ...157 297 ...
Страница 218: ...216 297 ...
Страница 220: ...218 297 ...
Страница 221: ... 2011 AB VOLVO PENTA Volvo reserves the right to make changes Printed on environmentally friendly paper 219 297 ...
Страница 222: ...7748681 English 12 2011 220 297 ...
Страница 223: ...9 2 Appendix B Alternator user and maintenance manual 221 297 ...
Страница 224: ...222 297 ...
Страница 226: ...224 297 ...
Страница 249: ...23 LEROY SOMER 2011 03 g Installation and maintenance LSA 47 2 4 POLES ALTERNATORS 3742 en 247 297 ...
Страница 250: ...www leroy somer com 248 297 ...
Страница 261: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 259 297 ...
Страница 281: ...2012 03 e LEROY SOMER 19 Installation and maintenance R 450 AVRs 4531 en 279 297 ...
Страница 282: ...www leroy somer com 280 297 ...