6.2.3
Switching off
trigger the circuit breaker located at the base of the centre console
Let the motor run under no load for 1 to 2 minutes to allow it to cool.
press the "STOP" button to stop the generating set.
switch off the MICS Nexys module by switching the key to "OFF" (without forcing it).
6.2.4
Alarms and faults
The appearance of a fault or an alarm causes the following
screen to be displayed (one or more pictograms or a fault
code along with the SOS message are displayed).
The user can access the following screens by pressing the key
The fault or alarm screen will disappear once the fault or alarm has been removed.
Only one fault is displayed on this screen (the fault which caused the generating set to stop).
If one or more faults have appeared after the first fault, they can only be displayed after the first fault has been reset
(press "Reset" as many times as the number of faults present).
Note
: an alarm can appear at the same time as a fault.
6.2.5
Faults and alarms - Details
List of faults which will cause the generating set to stop and generate a pictogram
Oil pressure fault: Indicates that the oil pressure is incorrect
Associated pictogram
Engine temperature fault: Indicates that the engine
temperature is too high.
Associated pictogram
Non-starting fault: Indicates that there have been three
consecutive unsuccessful starting attempts.
Associated pictogram
Overspeed fault: Indicates an excessive generating set
running speed.
Associated pictogram
Low fuel level fault: Indicates the need to top up the fuel.
Associated pictogram
56/242
Содержание R33C3
Страница 2: ......
Страница 61: ...The following diagram shows the structure of the main menu and how to go to each parameter 59 242 ...
Страница 94: ...92 242 ...
Страница 95: ...10 Appendix 10 1 Appendix A Engine user and maintenance manual 93 242 ...
Страница 96: ...94 242 ...
Страница 98: ...96 242 ...
Страница 115: ...113 242 ...
Страница 135: ...133 242 ...
Страница 145: ...143 242 ...
Страница 179: ...177 242 ...
Страница 191: ...July 2009 Pub No 99610 29120 OPERATION MAINTENANCE MANUAL 189 242 ...
Страница 192: ...Printed in Japan Pub No 99610 29120 190 242 ...
Страница 193: ...10 2 Appendix B Alternator user and maintenance manual 191 242 ...
Страница 194: ...192 242 ...
Страница 196: ...194 242 ...
Страница 227: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 225 242 ...
Страница 242: ...14 LEROY SOMER 2010 11 f Installation and maintenance R438 NOTES 3971 en 240 242 ...
Страница 243: ...LEROY SOMER 15 2010 11 f Installation and maintenance R438 NOTES 3971 en 241 242 ...