7 Parameter Description SV600 Series User Manual
112
In this curve, the rated motor frequency fb is always the inflexion point. This mode is usually
used in applications where acceleration/deceleration is required at the speed higher than the
rated frequency.
When the set frequency is higher than the rated frequency, the Acc./Dec. time is:
t=(4/9*(f/fb)^2+5/9)*T
In the formula, f is the set frequency, fb is the motor rated frequency and T is the Acc. time from
0 Hz to fb.
Function
code
Name
Setting range
Default
Property
P6-08
Time proportion of S-curve start segment
0.0% ~ (100.0%-P6-09)
30.0%
★
P6-09
Time proportion of S-curve end segment
0.0% ~ (100.0%-P6-08)
30.0%
★
These two parameters respectively define the time proportions of the start segment and the end
segment of S-curve acceleration/deceleration. They must satisfy the requirement: P6-08 + P6-09
≤ 100.0%.
Fig.7-10 S-curve Acc./Dec.A
Fig.7-11 S-curve Acc./Dec. B