- 6 -
Glykool 130+ Installation Instructions
This unit should be installed and serviced by a suitably trained person.
Sealed plugs may be fitted to new units.
Installation Procedure
•
Unpack the unit from its transportation packaging and visually inspect
for any signs of the damage.
•
Site the unit in a convenient location in the cellar or room and ensure
that the mains electricity supply is within 2 m and in an area allowing
free circulation of air.
•
The unit should be fitted with a correctly fused and wired 13 amp plug
or alternatively to a standard Euro plug to IEC83: 1975.
•
Site the heat dump in a convenient location, preferably in a non-heat
sensitive and shaded area on the outside of the building. If it cannot be
installed outside, ensure that the area is well ventilated and free from
other heat sources. Please check the Heat Dump General Guidelines
on page 5 for further details.
WARNING: THIS EQUIPMENT MUST BE EARTHED
The Wires in this Mains Lead are Coloured in accordance with the following
Code:
Green and Yellow Earth
Blue Neutral
Brown Live
As the Colours of the Wires in the Mains Lead of this Appliance may not
correspond with the Coloured Markings identifying the Terminals in the Plug to
be fitted proceed as follows:
•
The Wire which is coloured Green and Yellow MUST be connected to
the terminal in the Plug that is marked with the letter‚ E™ or by the
earth symbol, coloured Green or Green and Yellow.
•
The Wire which is coloured Blue MUST be connected to the Terminal
in the Plug that is marked with the letter‚ N™ or coloured Black.
•
The Wire which is coloured Brown MUST be connected to the Terminal
in the Plug that is marked with the letter‚ L™ or coloured Red.
The mains plug must be located in an accessible position.