- 19 -
Unit Type
Glykool 130+ Water Cooled Remote Cooler
Overall Dimensions
Height
Depth
Width
950 mm
660 mm
540 mm
Weight
Lid
Base
Heat Dump
Total Shipping Weight
Total Operating Weight
13 kg
52 kg
8.6 kg
75 kg
125 kg
Power Requirements
Mains Supply
Protection
Power Consumption
Fuse Requirements
220 V – 240 V 50 Hz
Must be installed with RCD
1597 W
13 A
Transformer
Input Voltage
Output Voltage
VA rating
Primary Fusing
Secondary Fusing
220 V – 240 V 50 Hz
24 V AC
90 VA
1 A (F1Amp)
6.25 A (T6.3Amp)
Product Coils
Length Options
Diameter
Material
No. Off 3.5m (short)
No. Off 8 m (medium)
No Off 12 m (long)
3.5 m up to 12 m
3/8” OD (10 mm)
316 Grade Stainless Steel
12 max
10 max
8 max
Refrigerant
Type
Amount
R134a (HFC)
375 g
Expansion Valve
Type
0.64 mm Capillary
Kleencare Kit
3 x 50ml Bottles
Application Label
One kit supplied with each unit
Electronic Control
Dimensions (HxWxD)
Voltage
Switch Capacity
Peak Switching Capacity
Power Consumption
Protection Class
Probe Accuracy
35 mm x 76 mm x 56 mm
220 V – 240 V 50-60 Hz
14 A
30 A for 4s
0.2 VA
IP 54 from front
+/- 0.05
°
C (-1
°
C to –18
°
C temperature range)
Heat Dump
Dimensions (HxWxD)
Weight
Fan Motor
Fan Blade
Cover
Water Connections
Flat Roof Mounting Bracket
360 mm x 3410 mm x 600 mm
8.6 kg
10 W 24 V AC
10” x 31
°
Pitch
ABS
15 mm Copper Tube (John Guest)
Option for floor standing operation