With reference to the attached drawing drill the surface onto which the heat dump is to be fitted at
the stated mounting hole centers ensuring that adequate clearance is allowed around the heat dump
to allow future access for cleaning.
Note - the wall mounting bracket can be used as a guide for marking its hole centers . Ensure that
the wall mounting bracket is mounted squarely to ensure level movement of the condenser matrix
when fitted.
Either mark the position of the third mounting screw at the time of marking the wall mounting bracket
position, or after fitting the wall mounting bracket hang the condenser matrix on, close against the
mounting surface and mark the fixing position.
Note - the third fixing screw will pass through the hole in the condenser matrix. The retaining clamp
is fitted over the screw which can then be tightened to retain the condenser matrix.
Connect the flow and return pipework from the glycol module and base unit to the fittings on the heat
dump labeled “FLOW” and “RETURN” and secure the pipes to the mounting surface so that the
weight of the pipes is not being carried on the heat dump fittings.
Note - Do not kink the pipework as this will restrict coolant flow.
Do not insulate the pipework. (Pipework mounted on an exterior surface may be insulated if
it is felt that due to extreme conditions freezing may occur).
Do not strap the flow and return pipes together as heat transfer between the two will effect
the systems performance.
Route a twin core 24 volt supply cable (1.5mm csa) through the lower guide tube and then through
the strain relief grommet positioned below the two way terminal block on the condenser matrix.
Note - The wires are not polarised and may be fitted either way round.
Ensure that the amount of cable entering through the main cover is not excessive and cannot
become entangled in the fan blade. Tighten the strain relief grommet to support the cable . This
should not be the only means of support for the cable, therefore fix back to the mounting surface at
regular intervals along the cable length.
6