METHODS OF CLEANING
NOTE:
Persons performing Cleansing /Sanitizing operations MUST be competent and fully
trained in safe methods of use of Cleansing / Sanitizing Agents and their applications.
NOTE:
PERSONAL PROTECTIVE EQUIPMENT SHOULD ALWAYS BE USED
.
NOTE:
DO NOT USE A WATER OR STEAM HOSE TO CLEAN THE UNIT
WHILST STILL INSTALLED.
NOTE:
IT IS IMPORTANT THAT ALL THE VENTS AND GRILLS ARE KEPT
CLEAR (inc.: Condenser grills where applicable)
TWICE ANNUALLY
:
By a competent Service \ Maintenance Engineer
a) Isolate unit from Mains Electricity Supply.
b) Clean sanitize the units cooling coils and product lines using Proprietary Cleanser / Sanitiser of
the Alkaline Hypochlorite type in accordance with the Manufacturers recommendations. Or
follow the direct cleaning recommendations laid down by the syrup supplier.
ANNUALLY:
By a Competent Service / Maintenance Engineer.
a) Isolate unit from Mains Electricity Supply.
b) Remove any extraneous debris from the unit or its casing preferably using a Vacuum cleaner or
brush, including the heat dump.
c) Check unit for electrical safety.
INSTRUCTIONS FOR SAFE USE OF CARBON DIOXIDE
See Carbon Dioxide warning notice at rear of booklet.
POWER ISOLATION METHOD
The unit is wired directly in to the mains electrical supply via an isolator box. The recommended
isolation method is as follows –
a) Switch the isolator box to the position marked off.
b) Remove the fuse ( preventing the unit from being inadvertently switched on).
PREVENTION OF FREEZING / ACTION REQUIRED IF FREEZING OCCURS.
It is recommended that the unit is sited In such a way as not to expose it to temperatures likely to
cause freezing i.e. below 0 deg C. If the Unit is to be sited in an unheated area then it would be wise
to insulate all Pipework and provide some form of Emergency Heating which should be controlled by
a Frost Stat. and sited in the close proximity to the Unit.
It should be noted that heat dumps may require to be sited where freezing may occur which is why a
30% glycol \ water mixture is used as a coolant. Failure to adhere to this recommendation could
result in damaging consequences. The concentration of the coolant should not be compromised,
and in the event of spillage, the lost volume should be replenished with the correct mixture.
In the event of Freezing Up occurring the following action is recommended:-
1. 1.Isolate the unit from Mains Electricity Supply.
11