2. 2.Disconnect the heat dump power cable.
3. Isolate Product Supply from unit.
4. Vent pressure lines by opening dispense tap.
5. Isolate from heat dump (Coolant lines) using service valve.
6. Apply gentle warmth to the general area of the unit and its Pipework.
7. Check for obvious leaks.
8. Turn water supply on whilst continually watching for leaks.
9. Reconnect product supply.
10. Reconnect Mains Electricity supply and heat dump supply.
11. Observe unit running for a short period watching out for Leaks, Strange noises or any other form
of malfunction, if no problems are observed then normal operation of the unit may be resumed.
MAX. / MIN. AMBIENT TEMPERATURES
.
COOLER UNIT - M10 ° C HEAT DUMP UNIT – Minimum –5°C
- M40 ° C - M40°C
MAX. / MIN. WATER PRESSURES
Minimum ----- 50 PSI (3.4 BAR)
Maximum ---- 60 PSI (4.1 BAR)
MAX. / MIN. CO2 PRESSURES
Minimum ----- 80 PSI (5.4 BAR)
Maximum ---- 90 PSI (6.1 BAR)
WARNING: THIS EQUIPMENT CAN CONTRIBUTE TO THE AMBIENT
TEMPERATURE.
WARNING: THIS UNIT IS UNSUITABLE FOR USE BY UNSUPERVISED
CHILDREN, AGED OR INFIRM PERSONS.
WARNING: PUMP PRESSURE TO CARBONATOR BOWL
13.2 BAR (200PSI).