IMPORTANT
The Wires in this Mains Lead are Coloured in accordance with the following Code:
Green and Yellow ----- Earth.
Blue ------------------------Neutral.
Brown --------------------- Live
As the Colours of the Wires in the Mains Lead of this Appliance may not correspond with the
Coloured Markings identifying the Terminals in the Plug to be fitted proceed as follows:
a) The Wire which is coloured Green and Yellow MUST be connected to the terminal in the Plug that
is marked with the letter ‚E™ or by the earth symbol, coloured Green or Green and yellow.
b) The Wire which is coloured Blue MUST be connected to the Terminal in the Plug that is marked
with the letter ‚N™ or coloured Black.
c) The Wire which is coloured Brown MUST be connected to the Terminal in the Plug that is marked
with the letter ‚L™ or coloured Red.
Dismantling / Decommissioning Procedure.
1. Isolate the unit from Mains Electricity Supply and the mains water supply.
2. Drain off all post mix products including the syrup and carbonated water (Clean syrup lines as
recommended by the syrup supplier)
3. Turn the CO2 off and disconnect all lines associated with the regulator, also vent pressure from
lines by purging the product valves as required.
4. Disconnect all post mix pipework and remove dispense head equipment, including the python.
and remove as recommended by the equipment owner.
5. Siphon or pump out water from the waterbath to a suitable drainage point.
6. Allow ice bank to melt (the careful use of hot water may be used to accelerate this process).
Remove any remaining water from melting the ice.
7. Drain all the glycol \ water from water cooled units into a suitable container and dispose of it in
accordance with the instructions given by the dispense equipment owner.
WARNING:
FAILURE TO REMOVE ALL ICE / WATER COULD RESULT IN
SUBSTANTIAL AMOUNTS OF WATER BEING RELEASED FROM
THE UNIT WHICH MAY BE DETRIMENTAL TO THE UNIT AND/OR
ITS SURROUNDINGS AND INCREASE THE MAXIMUM WEIGHT
OF THE UNIT.
Adjustment / Maintenance Requirements.
It is not recommended that the End User makes any adjustments or carries out any Maintenance
other than:
a) Check the mains lead and plug Visually for condition.
b) Check the unit and its Pipework for evidence of leaks visually, including the heat dump.
c) Check that the condenser grill and vents are not choked or obscured, including the heat dump.
d) If there is any spillage of liquid onto the unit, isolate the power supply before cleaning up.
e) Make any necessary adjustments as recommended by the syrup supplier.
NOTE:
THERE ARE NO USER SERVICEABLE PARTS